Operating ambient temperatures
Suggested retail price
Description
The ESG series aims to create a future Net-Zero heat pump that meets the sustainable development strategy in terms of production/materials/equipment useb and provides a comfortable temperature for the pool and a comfortable temperature for the environment.
Heating&Cooling - ESG heat pump contains heating and cooling and automatic modes, covering a wide range of operating environment
temperature and target water temperature
Pool system centralized control - ESG heat pump is compatible with all centralized control pool systems using Modbus protocol and RS485 connector
IOT&APP - App controls and IOT platforms are designed to ensure user ease of operation and reduce equipment maintenance costs
Specifications
MODEL | MSC‐70D2N8‐A | MSC‐90D2N8‐A | MSC‐120D2N8‐A | ||
Power supply | 220‐240V~ 50Hz | 220‐240V~ 50Hz | 220‐240V~ 50Hz | ||
Heating (A27/24.3℃, W28℃) |
Capacity | kW | 7.16 | 9.15 | 12.50 |
Rated input | kW | 0.95 | 1.35 | 1.79 | |
COP | 7.50 | 6.80 | 7.00 | ||
Boost Heating (A27/24.3℃, W28℃) |
Capacity | kW | 10.30 | 12.80 | 14.50 |
Rated input | kW | 1.56 | 2.13 | 2.28 | |
COP | 6.60 | 6.00 | 6.35 | ||
Heating (A15/12℃, W28℃) |
Capacity | kW | 5.30 | 6.80 | 9.12 |
Rated input | kW | 1.04 | 1.39 | 1.81 | |
COP | 5.10 | 4.90 | 5.05 | ||
Boost Heating (A15/12℃, W28℃) |
Capacity | kW | 7.30 | 9.30 | 10.50 |
Rated input | kW | 1.56 | 2.09 | 2.28 | |
COP | 4.69 | 4.45 | 4.60 | ||
Heating (A7/6℃, W28℃) |
Capacity | kW | 4.40 | 5.00 | 7.60 |
Rated input | kW | 1.05 | 1.28 | 1.77 | |
COP | 4.20 | 3.90 | 4.30 | ||
Heating (A2/1℃, W28℃) |
Capacity | kW | 3.40 | 4.20 | 5.50 |
Rated input | kW | 0.94 | 1.22 | 1.53 | |
COP | 3.60 | 3.45 | 3.60 | ||
Cooling (A35/‐℃, W28℃) |
Capacity | kW | 4.50 | 5.20 | 7.00 |
Rated input | kW | 1.13 | 1.55 | 1.75 | |
EER | 4.00 | 3.35 | 4.00 | ||
Cooling (A43/‐℃, W28℃) |
Capacity | kW | 3.40 | 3.60 | 5.10 |
Rated input | kW | 1.31 | 1.44 | 1.59 | |
EER | 2.60 | 2.50 | 3.20 | ||
Max. running input | W | 2200 | 2600 | 2800 | |
Max. running current | A | 10.5 | 11.0 | 12.0 | |
Compressor | Type | DC Rotary | DC Rotary | DC Rotary | |
Oil type | ESTER OIL VG74 | ESTER OIL VG74 | ESTER OIL VG74 | ||
Oil charged | ml | 420 | 420 | 420 | |
Outdoor fan | Motor type | DC Brushless | DC Brushless | DC Brushless | |
Number of fans | 1 | 1 | 1 | ||
Air flow | m3/h | 3200 | 3800 | 3900 | |
Air side heat exchanger | Type | Finned tube | Finned tube | Finned tube | |
Refrigerant | Type | R32 | R32 | R32 | |
GWP | 675 | 675 | 675 | ||
Charged volume | kg | 0.55 | 0.55 | 0.75 | |
Throttle type | EXV | EXV | EXV | ||
Water side heat exchanger | Material | Titanium | Titanium | Titanium | |
Water side connection | Type | Internal thread Glue connection |
Internal thread Glue connection |
Internal thread Glue connection |
|
mm | φ50 | φ50 | φ50 | ||
Water flow range | m3/h | 3.1 | 3.9 | 5.4 | |
Water pressure drop | kPa | 4.6 | 7.3 | 13.8 | |
Sound presssure Level | Heating (A27/24.3℃, W28℃) | dB(A) | 41 | 43 | 49 |
Heating max | dB(A) | 48 | 52 | 55 | |
heating slince mode1 | dB(A) | 39 | 39 | 40 | |
heating slince mode2 | dB(A) | 38 | 38 | 38 | |
Cooling (A35/‐℃, W28℃) | dB(A) | 43 | 45 | 48 | |
Cooling max | dB(A) | 43 | 45 | 48 | |
Cooling slince mode1 | dB(A) | 40 | 41 | 43 | |
Cooling slince mode2 | dB(A) | 39 | 40 | 40 | |
Unit dimension (W×H×D) | mm | 988×426×712 | 988×426×712 | 988×426×712 | |
Packing dimension (W×H×D) | mm | 1065×485×845 | 1065×485×845 | 1065×485×845 | |
Net weight | kg | 46 | 46 | 50 | |
Gross weight | kg | 53 | 53 | 57 | |
Ambient temperature range | Cooling | ⁰C | 15~43 | 15~43 | 15~43 |
Heating | ⁰C | ‐7~43 | ‐7~43 | ‐7~43 | |
Water inlet temperature setting range |
Cooling | ⁰C | 12~30 | 12~30 | 12~30 |
Heating | ⁰C | 10~40 | 10~40 | 10~40 | |
Nominal outlet water temperature range |
Cooling | ⁰C | 10~28 | 10~28 | 10~28 |
Heating | ⁰C | 12~42 | 12~42 | 12~42 |
Electrical characteristics | ||||||||||
Model | Outdoor unit | Power current | Compressor | Fan motor | ||||||
Voltage (V) |
Hz | Min. (V) |
Max. (V) |
MCA (A) |
TOCA (A) |
MFA (A) |
RLA (A) |
kW | FLA (A) |
|
MSC-70D2N8-A | 230 | 50 | 198 | 264 | 10.5 | 14.0 | 16.0 | 6.8 | 0.05 | 0.4 |
MSC-90D2N8-A | 230 | 50 | 198 | 264 | 11.0 | 14.0 | 16.0 | 9.3 | 0.08 | 0.5 |
MSC-120D2N8-A | 230 | 50 | 198 | 264 | 12.0 | 14.0 | 16.0 | 10.0 | 0.11 | 0.7 |
Note: | ||||||||||
MCA: Min. circuit amps.(For wire diameter selection) | ||||||||||
TOCA: Total over‐current amps(For air‐break switch selection) MFA: Max. fuse amps(For fuse selection) | ||||||||||
RLA: Rated load amps. The input amps of compressor where maximum Hz can operate for nominal cooling or heating test condition | ||||||||||
kW: Rated motor output |
Video
Inverter heat pump for pools ESG-Inv M series
Meet Midea’s latest 0 carbon energy solution - the ESG-Inv M Series Inverter Pool Heat Pump, designed to maintain your pool water at an optimal temperature, is an efficient and powerful system that runs on smart technology. With an intelligent IoT platform and multiple protection functions, this heat pump will provide reliable performance at low maintenance costs. Watch now to get inspired!