Midea "Heat pump for pools ESG-Inv M series"

Operating ambient temperatures

Cooling mode
+ 15
... + 43 °C
Heating mode
- 7
... + 43 °C

Suggested retail price

81,795-hrv.

    The ESG series aims to create a future Net-Zero heat pump that meets the sustainable development strategy in terms of production/materials/equipment useb and provides a comfortable temperature for the pool and a comfortable temperature for the environment.

    Heating&Cooling - ESG heat pump contains heating and cooling and automatic modes, covering a wide range of operating environment
    temperature and target water temperature

    Pool system centralized control - ESG heat pump is compatible with all centralized control pool systems using Modbus protocol and RS485 connector

    IOT&APP - App controls and IOT platforms are designed to ensure user ease of operation and reduce equipment maintenance costs

    SG-Ready - SG-ready ensures that ESG heat pump uses as much clean energy as possible from the smart grid and stores the energy in the swimming pool. When the smart grid is fully supplied with clean energy, ESG heat pumps consume close to zero carbon

    MODEL MSC‐70D2N8‐A MSC‐90D2N8‐A MSC‐120D2N8‐A
    Power supply 220‐240V~ 50Hz 220‐240V~ 50Hz 220‐240V~ 50Hz
    Heating
    (A27/24.3℃, W28℃)
    Capacity kW 7.16 9.15 12.50
    Rated input kW 0.95 1.35 1.79
    COP 7.50 6.80 7.00
    Boost Heating
    (A27/24.3℃, W28℃)
    Capacity kW 10.30 12.80 14.50
    Rated input kW 1.56 2.13 2.28
    COP 6.60 6.00 6.35
    Heating
    (A15/12℃, W28℃)
    Capacity kW 5.30 6.80 9.12
    Rated input kW 1.04 1.39 1.81
    COP 5.10 4.90 5.05
    Boost Heating
    (A15/12℃, W28℃)
    Capacity kW 7.30 9.30 10.50
    Rated input kW 1.56 2.09 2.28
    COP 4.69 4.45 4.60
    Heating
    (A7/6℃, W28℃)
    Capacity kW 4.40 5.00 7.60
    Rated input kW 1.05 1.28 1.77
    COP 4.20 3.90 4.30
    Heating
    (A2/1℃, W28℃)
    Capacity kW 3.40 4.20 5.50
    Rated input kW 0.94 1.22 1.53
    COP 3.60 3.45 3.60
    Cooling
    (A35/‐℃, W28℃)
    Capacity kW 4.50 5.20 7.00
    Rated input kW 1.13 1.55 1.75
    EER 4.00 3.35 4.00
    Cooling
    (A43/‐℃, W28℃)
    Capacity kW 3.40 3.60 5.10
    Rated input kW 1.31 1.44 1.59
    EER 2.60 2.50 3.20
    Max. running input W 2200 2600 2800
    Max. running current A 10.5 11.0 12.0
    Compressor Type DC Rotary DC Rotary DC Rotary
    Oil type ESTER OIL VG74 ESTER OIL VG74 ESTER OIL VG74
    Oil charged ml 420 420 420
    Outdoor fan Motor type DC Brushless DC Brushless DC Brushless
    Number of fans 1 1 1
    Air flow m3/h 3200 3800 3900
    Air side heat exchanger Type Finned tube Finned tube Finned tube
    Refrigerant Type R32 R32 R32
    GWP 675 675 675
    Charged volume kg 0.55 0.55 0.75
    Throttle type EXV EXV EXV
    Water side heat exchanger Material Titanium Titanium Titanium
    Water side connection Type Internal thread
    Glue connection
    Internal thread
    Glue connection
    Internal thread
    Glue connection
    mm φ50 φ50 φ50
    Water flow range m3/h 3.1 3.9 5.4
    Water pressure drop kPa 4.6 7.3 13.8
    Sound presssure Level Heating (A27/24.3℃, W28℃) dB(A) 41 43 49
    Heating max dB(A) 48 52 55
    heating slince mode1 dB(A) 39 39 40
    heating slince mode2 dB(A) 38 38 38
    Cooling (A35/‐℃, W28℃) dB(A) 43 45 48
    Cooling max dB(A) 43 45 48
    Cooling slince mode1 dB(A) 40 41 43
    Cooling slince mode2 dB(A) 39 40 40
    Unit dimension (W×H×D) mm 988×426×712 988×426×712 988×426×712
    Packing dimension (W×H×D) mm 1065×485×845 1065×485×845 1065×485×845
    Net weight kg 46 46 50
    Gross weight kg 53 53 57
    Ambient temperature range Cooling ⁰C 15~43 15~43 15~43
    Heating ⁰C ‐7~43 ‐7~43 ‐7~43
    Water inlet temperature
    setting range
    Cooling ⁰C 12~30 12~30 12~30
    Heating ⁰C 10~40 10~40 10~40
    Nominal outlet water
    temperature range
    Cooling ⁰C 10~28 10~28 10~28
    Heating ⁰C 12~42 12~42 12~42
    Electrical characteristics                
    Model Outdoor unit Power current Compressor Fan motor
    Voltage
    (V)
    Hz Min.
    (V)
    Max.
    (V)
    MCA
    (A)
    TOCA
    (A)
    MFA
    (A)
    RLA
    (A)
    kW FLA
    (A)
    MSC-70D2N8-A 230 50 198 264 10.5 14.0 16.0 6.8 0.05 0.4
    MSC-90D2N8-A 230 50 198 264 11.0 14.0 16.0 9.3 0.08 0.5
    MSC-120D2N8-A 230 50 198 264 12.0 14.0 16.0 10.0 0.11 0.7
    Note:                    
    MCA: Min. circuit amps.(For wire diameter selection)            
    TOCA: Total over‐current amps(For air‐break switch selection) MFA: Max. fuse amps(For fuse selection)    
    RLA: Rated load amps. The input amps of compressor where maximum Hz can operate for nominal cooling or heating test condition
    kW: Rated motor output                  

    Inverter heat pump for pools ESG-Inv M series

    Meet Midea’s latest 0 carbon energy solution - the ESG-Inv M Series Inverter Pool Heat Pump, designed to maintain your pool water at an optimal temperature, is an efficient and powerful system that runs on smart technology. With an intelligent IoT platform and multiple protection functions, this heat pump will provide reliable performance at low maintenance costs. Watch now to get inspired!