Main functions
Operating ambient temperatures
As a rule, floor-to-ceiling split systems are used when it is necessary to provide air conditioning for large halls in “markets”, “Open Space” offices, restaurants, cafes, etc.
Technology
3D Air Flow
The unit has auto horizontal swing and auto vertical swing function, which supplies more even and comfortable air flow.
Silence
The "Silence" - air conditioning reduces the fan speed of the indoor unit to a minimum, with the noise of the air conditioner as well reduced.
Aluminium heat exchanger with hydrophilic coating
Improved wettability of the heat exchanger aluminum plates which have a special coating with a hydrophilic layer, ensuring rapid removal of condensate from the indoor unit that does not allow to quickly form of mold and bacteria, providing a more efficient operation of the air conditioner.
Compresor DC inverter
Compressor with inverter DC can increase the efficiency of the air conditioner, thus reducing power consumption saves your costs. This system is much more economical and safer than air conditioners with a constant output of the compressor.
Wi-Fi Control (Wi-Fi stick)
Mission's Wi-Fi and Smart Kits* are designed for even more comfortable and easy operation (for some series of Wi-Fi stick - option).
Customers can download absolutely free app for your smartphone with the QR-code located in the user's manual.
Motor DC inverter indoor unit
The indoor unit is used to rotate the impeller DC - motor. This can significantly reduce noise and power consumption. And also get 12 positions change the speed of the impeller.
DC inverter motor Outdoor Unit
In outdoor units, a DC motor is used to rotate the fan. This allows you to significantly reduce noise and power consumption. And also get several positions of the fan speed, depending on the needs of the system.
Night Mode
Mode is activated with the remote control and provides a comfortable environment for a peaceful and deep sleep during the 7-hour cycle with a temperature change of reference values, as well as setting the minimum noise level and economical energy consumption. After that, the temperature returns to the originally specified value.
Refrigerant Leakage Detect
Its a electronical function of Main PCB and self-diagnostic system into AC.
When pipe-temperature sensor at inlet line of evaporator will indicate highest temperature, system will indicate "EC" code in a display of indoor units, its mean "ask for service centre for visit maintance team with leakage detectors and tools"
Ozone-friendly freon R32
The new refrigerant R32 (difluoromethane) has significant advantages. First of all, it concerns the potential of global warming (GWP). If we compare the highly popular R410A refrigerant with R32, the latter differs by more than 65% of the GWP reduced. It follows that the environment is less affected by the new refrigerant. Also, R32 is characterized by reduced viscosity and density. Due to the lower density, the freon consumption is reduced, taking into account the same power figures. The density of difluoromethane is almost 30% less than that of R410A.
Low Ambient Cooling
Low-temperature (season) set - used for the operation of the air conditioner in cooling mode at low ambient temperatures (usually provided in the air conditioner as an optional feature). The kit includes: the controller of the outdoor unit fan motor, compressor crankcase heater and heater drain line.
In some series of inverter split systems this option is implemented in hardware and software, thus if there is a need to use the air conditioner in the winter for cooling, you must install only drain the heater.
Maintaining temperature +8°С
Protection against freezing of the room, maintaining the temperature of +8°C.
The control system of air conditioners can keep the room air temperature +8°C, so as not to cool the walls and freeze the water pipe. It is actual to use for summer residences, garages or if you leave on leave in the winter, and the constant warming up of a premise to a comfortable temperature is not required. At the same time, the air conditioner consumes less electricity, because the temperature difference between the street / room is also reduced.
The mixing of fresh air
Organization of fresh air - by a separate duct (in a split system with such a function, the duct is usually a small diameter and is laid along the highway) ...
Crankcase Heater
To prevent the compressor's hydraulic impact, when the split system is in operation, in the cold season (at negative outdoor temperatures), an electric TEN is installed. The heating element is turned on when the compressor is stopped and does not allow condensed liquid freon in the oil in the compressor crankcase.
The heater of the outdoor unit pallet
The heater of the outdoor unit pallet is installed to ensure complete removal of water from the heat exchanger of the outdoor unit resulting from defrost during the defrosting operation.
Wired remote control for indoor unit
The internal block is completed / can be completed (option) with the wire control panel.
General functional features:
- Connection to indoor units using stranded wire.
- The job modes.3. Set the fan speed.
- Display information about operating modes on the LCD.
- Setting the time of automatic on / off using a timer.
Dry Mode
Dry mode automatically selects cooling, based on the difference between fixed and temparaturoy actual room temperature. The temperature is regulated while reducing humidity repeated switching on and off of the cooling and ventilation only. when the dry mode on the remote control shows "Drop"
Temperature compensation
The function of temperature compensation corrects the temperature in the person's zone of being comfortable, (because the air temperature near the floor and ceiling can differ by several degrees) by further increasing / decreasing the temperature from the value set from the remote control. Thus, compensation and equalization of the overall room temperature occurs. For household split systems, the value is set by the manufacturer and is 2°C.
Multi-Bend Heat Exchanger
Increased heat. This unit uses the heat exchangers with tubes of a special design, the inner surface of which has trapezoidal notches "Innergrove cooper", which provides maximum heat transfer surface area increased. Due to this heat increases by 28%, reduced power consumption, and hence increases the efficiency of the system.
Full-DC (3D DC-inverter)
All engines compressors and fans in the system are made by DC-inverter technology.
Sine-Wave Inverter
Technology 180° -gradusnogo wave inverter conversion - control voltage without the "pulse" effects (jagged sinusoid).
Compared with the current standard of 120° rectangular wave has the following advantages:
- Ability to work with a wider range of supply voltage and frequency.
- Most of the energy efficiency and energy conservation.
- More soft start, lower noise and vibration.
- more control.
Reserved ON-OFF and Alarm Ports
ON-OFF Switch: With the reserved ports, a remote switch can be easily connected to a realize remote control. Alarm Port: The built-in PCB can output alarm signal, which makes setting up an external alarm light or vibration gauge possible.
Wide angle air flow
The vertical louvers of Midea air conditioners swing at an angle of 110° (ordinary air conditioners only swing at 80°), while the horizontal louvers swing at 120° (ordinary air conditioners only swing at 90°). These more flexible louvers provide cooling which is wider and more even.
Energy efficiency А+++
Energy efficiency is the effective (rational) use of energy resources. Use less energy to provide the same level of energy supply to buildings or manufacturing processes.
Specifications
The Indoor Unit
Power, kW
Power consumption, kW
Energy Efficiency Class
Energy Efficiency Ratio
Diameter Pipes, mm
Dimensions(WxHxD), mm
Weight, kg
The outdoor Unit
Freon
Diameter Pipes, mm
Dimensions(WxHxD), mm
Weight, kg
Video
Soft Midea AIR Setup Wi-Fi
Soft Midea AIR Setup Wi-Fi