Midea MTB DC (2018) MTB-48HRFN /MOU-48HRFN1-R air conditioner

Suggested retail price

136 325,-hrv.

Main functions

2-way Draining
24-hour timer
3-minute protection feature
Anti-Cold Air Function
Anti-corrosion coating of the heat exchanger
Auto-restart
Auto-unfreezing
Cooling-Heating
Effective drainage
Fresh Air
IR Remote Control
Low noise level
Refrigerant Leakage Detect
Self-diagnosis function
Built-in drain pump
The central group control panel
WiFi Module
Wired Remote Control

Operating ambient temperatures

Cooling mode
- 15
... + 50 °C
Heating mode
- 15
... + 24 °C
    Technology

    Blue Fin

    Blue fin heat exchanger cover - Protection against corrosion. Special anti-corrosion coating of the heat exchanger, protection from atmospheric phenomena and effects of aggressive environment. May differ in color (have blue, green, gold or no color at all (clear varnish)

    Sine-Wave Inverter

    Technology 180° -gradusnogo wave inverter conversion - control voltage without the "pulse" effects (jagged sinusoid).

    Compared with the current standard of 120° rectangular wave has the following advantages:

    1. Ability to work with a wider range of supply voltage and frequency.
    2. Most of the energy efficiency and energy conservation.
    3. More soft start, lower noise and vibration.
    4. more control.

    Refrigerant Leakage Detect

    Its a electronical function of Main PCB and self-diagnostic system into AC.

    When pipe-temperature sensor at inlet line of evaporator will indicate highest temperature, system will indicate "EC" code in a display of indoor units, its mean "ask for service centre for visit maintance team with leakage detectors and tools"

    Compresor DC inverter

    Compressor with inverter DC can increase the efficiency of the air conditioner, thus reducing power consumption saves your costs. This system is much more economical and safer than air conditioners with a constant output of the compressor.

    Night Mode

    Mode is activated with the remote control and provides a comfortable environment for a peaceful and deep sleep during the 7-hour cycle with a temperature change of reference values​​, as well as setting the minimum noise level and economical energy consumption. After that, the temperature returns to the originally specified value.

    Dry Mode

    Dry mode automatically selects cooling, based on the difference between fixed and temparaturoy actual room temperature. The temperature is regulated while reducing humidity repeated switching on and off of the cooling and ventilation only. when the dry mode on the remote control shows "Drop"

    Temperature compensation

    The function of temperature compensation corrects the temperature in the person's zone of being comfortable, (because the air temperature near the floor and ceiling can differ by several degrees) by further increasing / decreasing the temperature from the value set from the remote control. Thus, compensation and equalization of the overall room temperature occurs. For household split systems, the value is set by the manufacturer and is 2°C.

    Multi-Bend Heat Exchanger

    Increased heat. This unit uses the heat exchangers with tubes of a special design, the inner surface of which has trapezoidal notches "Innergrove cooper", which provides maximum heat transfer surface area increased. Due to this heat increases by 28%, reduced power consumption, and hence increases the efficiency of the system.

    Low Ambient Cooling

    Low-temperature (season) set - used for the operation of the air conditioner in cooling mode at low ambient temperatures (usually provided in the air conditioner as an optional feature). The kit includes: the controller of the outdoor unit fan motor, compressor crankcase heater and heater drain line.

    In some series of inverter split systems this option is implemented in hardware and software, thus if there is a need to use the air conditioner in the winter for cooling, you must install only drain the heater.

    The Indoor Unit

    Model Name
    MTB-48HRFN1
    Power Options, V/Hz/Ph
    220/50/1

    Power, kW

    Cooling Power
    4.100
    ... 16.100
    Heating Capacity
    4.340
    ... 18.130

    Power consumption, kW

    Cooling
    1.370
    ... 6.310
    Heating
    1.450
    ... 6.480
    Static pressure is nominal (Rated), Pa
    100
    Air flow rate, m³/h
    2,300
    ... 1,600
    Sound Pressure Level, dB(A)
    50.00
    ... 44.00
    Sound Power Level, dB(A)
    68.00
    Drain pipes diameter, mm
    25 mm

    Dimensions(WxHxD), mm

    Without Package
    1200
    x 300
    x 865
    in Multiples
    1405
    x 373
    x 920

    Weight, kg

    Net Weight
    43.00
    Gross Weight
    52.00

    The outdoor Unit

    Model Name
    MOE30U-48HFN1-S
    Compressors Type
    Inverter
    Compressor
    GMCC ROTARY DC

    Freon

    Freon Type
    R410A
    Freon Weight, kg
    4.00, kg
    Power Options, V/Hz/Ph
    380/50/3
    Air flow rate, m3/h
    7,200
    ... 720
    Sound Pressure Level, dB(A)
    65.00

    Diameter Pipes, mm

    Liquid
    9.52
    Gas
    15.90
    Min length of main line, m
    3
    Max length of main line, m
    65
    Max vertical drop, m
    30

    Dimensions(WxHxD), mm

    Without Package
    952
    x 1333
    x 410
    in Multiples
    1095
    x 1470
    x 500

    Weight, kg

    Net Weight
    95.00
    Gross Weight
    108.00