Operating ambient temperatures
Suggested retail price
Technology
Blue Fin
Blue fin heat exchanger cover - Protection against corrosion. Special anti-corrosion coating of the heat exchanger, protection from atmospheric phenomena and effects of aggressive environment. May differ in color (have blue, green, gold or no color at all (clear varnish)
Aluminium heat exchanger with hydrophilic coating
Improved wettability of the heat exchanger aluminum plates which have a special coating with a hydrophilic layer, ensuring rapid removal of condensate from the indoor unit that does not allow to quickly form of mold and bacteria, providing a more efficient operation of the air conditioner.
Refrigerant Leakage Detect
Its a electronical function of Main PCB and self-diagnostic system into AC.
When pipe-temperature sensor at inlet line of evaporator will indicate highest temperature, system will indicate "EC" code in a display of indoor units, its mean "ask for service centre for visit maintance team with leakage detectors and tools"
PTC Heater
Air conditioning as standard (optional) can be equipped with electric heaters PTC Heater (ceramic heater-s), which allows to use the air conditioner in the winter as a powerful heater, regardless of the temperature outside.
Night Mode
Mode is activated with the remote control and provides a comfortable environment for a peaceful and deep sleep during the 7-hour cycle with a temperature change of reference values, as well as setting the minimum noise level and economical energy consumption. After that, the temperature returns to the originally specified value.
Dry Mode
Dry mode automatically selects cooling, based on the difference between fixed and temparaturoy actual room temperature. The temperature is regulated while reducing humidity repeated switching on and off of the cooling and ventilation only. when the dry mode on the remote control shows "Drop"
Description
Column Mide air conditioners are ideal for cooling and heating of premises with large volume, where more power is required, but you can not use for the installation of HVAC equipment wall and ceiling (for example, when the room is a large glass area and high ceilings).
MFM Series Features:
- Modern design;
- High performance;
- Control via the front panel buttons;
- Multifunction LED display shows the operating modes and information of any faults;
- Auto-Restart;
- Heating by electric heaters;
- Easy installation;
- Wide and powerful airflow.
Specifications
Model Indoor | MFM-60ARN1-S | ||
Model Outdoor | MOUL-60HN1-S | ||
Power supply | V-ph-Hz | 380-3-50 | |
Cooling | Capacity | Btu/h | 57900 |
Input | W | 6500 | |
Rated current | A | 11.0 | |
EER | W/W | 2.61 | |
Heating | Capacity | Btu/h | 62000+12000 |
Input | W | 5300+3700 | |
Rated current | A | 10.0+5.3 | |
COP | W/W | 3,43 | |
Max. input consumption | W | 8200+3700 | |
Max. current | A | 14.7+5.3 | |
Starting current | A | 67 | |
Compressor | Type | SCROLL | |
Brand | PANASONIC | ||
Thermal protector position | INTERNAL | ||
Capacitor | uF | - - | |
Outdoor noise level | dB(A) | 64 | |
Outdoor unit | Dimension(W*D*H) | mm | 900x350x1170 |
Packing (W*D*H) | mm | 1032x443x1307 | |
Net/Gross weight | Kg | 96 / 107 | |
Refrigerant type | g | R410A/3200g | |
Design pressure | MPa | 4.2/1.5 | |
Refrigerant piping | Liquid side/ Gas side | mm(inch) | Φ12.7/Φ19(1/2"/3/4") |
Max. refrigerant pipe length | m | 50 | |
Max. difference in level | m | 30 | |
Connection wiring | mm2 | 2.5(Optional) | |
Operation temperature | ℃ | 17-30 | |
Room temperature | Indoor(cooling/ heating) | ℃ | 17-32/0-30 |
Outdoor(cooling/heating) | ℃ | 18-43/-7-24 | |
Application area | m2 | 77-113 |