Main functions
Operating ambient temperatures
Technology
Blue Fin
Blue fin heat exchanger cover - Protection against corrosion. Special anti-corrosion coating of the heat exchanger, protection from atmospheric phenomena and effects of aggressive environment. May differ in color (have blue, green, gold or no color at all (clear varnish)
Silence
The "Silence" - air conditioning reduces the fan speed of the indoor unit to a minimum, with the noise of the air conditioner as well reduced.
Aluminium heat exchanger with hydrophilic coating
Improved wettability of the heat exchanger aluminum plates which have a special coating with a hydrophilic layer, ensuring rapid removal of condensate from the indoor unit that does not allow to quickly form of mold and bacteria, providing a more efficient operation of the air conditioner.
360°Air Flow Panel
With the 360°air flow panel, the air can be distributed to every corner of the room.
Outdoor unit design "Brilliant"
Designers Midea did not forget about the exterior of the exterior unit of the air conditioner, which in itself is a rarity for climate technology. The outdoor unit is much more elegant than its counterparts, it has facets like a diamond, and attention to detail speaks of a high level of production and a carefully thought-out design concept.
Night Mode
Mode is activated with the remote control and provides a comfortable environment for a peaceful and deep sleep during the 7-hour cycle with a temperature change of reference values, as well as setting the minimum noise level and economical energy consumption. After that, the temperature returns to the originally specified value.
Refrigerant Leakage Detect
Its a electronical function of Main PCB and self-diagnostic system into AC.
When pipe-temperature sensor at inlet line of evaporator will indicate highest temperature, system will indicate "EC" code in a display of indoor units, its mean "ask for service centre for visit maintance team with leakage detectors and tools"
Redirecting the flow of air to neighboring rooms using air ducts
With the help of air ducts, it is possible to organize the redirection of part of the treated air flow to neighboring rooms.
The mixing of fresh air
Organization of fresh air - by a separate duct (in a split system with such a function, the duct is usually a small diameter and is laid along the highway) ...
Dry Mode
Dry mode automatically selects cooling, based on the difference between fixed and temparaturoy actual room temperature. The temperature is regulated while reducing humidity repeated switching on and off of the cooling and ventilation only. when the dry mode on the remote control shows "Drop"
Multi-Bend Heat Exchanger
Increased heat. This unit uses the heat exchangers with tubes of a special design, the inner surface of which has trapezoidal notches "Innergrove cooper", which provides maximum heat transfer surface area increased. Due to this heat increases by 28%, reduced power consumption, and hence increases the efficiency of the system.