Midea MCD-60HRFN1-S /MOE30U-60HFN1-S air conditioner (Archived Models)

Suggested retail price

0,-hrv.

Main functions

24-hour timer
3-minute protection feature
Air outlet in all directions
Anti-Cold Air Function
Anti-corrosion coating of the heat exchanger
Auto-restart
Auto-unfreezing
Automatic operation of the horizontal blinds
Built-in drain pump
Cooling-Heating
Effective drainage
Fresh Air
IR Remote Control
LED display
Low noise level
Night Mode
Refrigerant Leakage Detect
Self-diagnosis function
Small height of the housing
The central group control panel
WiFi Module
Wired Remote Control
Ionizer

Operating ambient temperatures

Cooling mode
- 15
... + 43 °C
Heating mode
- 15
... + 24 °C

Eurovent CertifiedThis model of semi-industrial split system has been successfully tested for compliance with a number of technical parameters, according to Eurovent standards.

This fact confirms the high quality of products and full compliance with the expectations of customers worldwide, as the company produces air conditioners for all major world markets, offers sales and service support through its distribution network on all continents. Only the most renowned and popular global air conditioner manufacturers have submitted their certification products to Eurovent Laboratories, which carefully analyze the full range of characteristics and perform critical test kits for the factory-approved device parameters.

    Technology

    Blue Fin

    Blue fin heat exchanger cover - Protection against corrosion. Special anti-corrosion coating of the heat exchanger, protection from atmospheric phenomena and effects of aggressive environment. May differ in color (have blue, green, gold or no color at all (clear varnish)

    Silence

    The "Silence" - air conditioning reduces the fan speed of the indoor unit to a minimum, with the noise of the air conditioner as well reduced.

    Sine-Wave Inverter

    Technology 180° -gradusnogo wave inverter conversion - control voltage without the "pulse" effects (jagged sinusoid).

    Compared with the current standard of 120° rectangular wave has the following advantages:

    1. Ability to work with a wider range of supply voltage and frequency.
    2. Most of the energy efficiency and energy conservation.
    3. More soft start, lower noise and vibration.
    4. more control.

    The Ionizer

    Air purification system is provided with a high-efficiency air conditioner ionizer that produces millions of negative ions that neutralize all the harmful elements present in your home. Negatively charged ions attract the dust particles, bacteria, mold spores and viruses, neutralize them, supporting chichtotu and freshness of the air in the room.

    The ionizer is usually located on the left side of the housing of the indoor unit under the blinds (see photo below). On some series of domestic and semi-industrial split systems, it can be installed optionally)

    Refrigerant Leakage Detect

    Its a electronical function of Main PCB and self-diagnostic system into AC.

    When pipe-temperature sensor at inlet line of evaporator will indicate highest temperature, system will indicate "EC" code in a display of indoor units, its mean "ask for service centre for visit maintance team with leakage detectors and tools"

    Compresor DC inverter

    Compressor with inverter DC can increase the efficiency of the air conditioner, thus reducing power consumption saves your costs. This system is much more economical and safer than air conditioners with a constant output of the compressor.

    Night Mode

    Mode is activated with the remote control and provides a comfortable environment for a peaceful and deep sleep during the 7-hour cycle with a temperature change of reference values​​, as well as setting the minimum noise level and economical energy consumption. After that, the temperature returns to the originally specified value.

    Dry Mode

    Dry mode automatically selects cooling, based on the difference between fixed and temparaturoy actual room temperature. The temperature is regulated while reducing humidity repeated switching on and off of the cooling and ventilation only. when the dry mode on the remote control shows "Drop"

    Multi-Bend Heat Exchanger

    Increased heat. This unit uses the heat exchangers with tubes of a special design, the inner surface of which has trapezoidal notches "Innergrove cooper", which provides maximum heat transfer surface area increased. Due to this heat increases by 28%, reduced power consumption, and hence increases the efficiency of the system.

    Low Ambient Cooling

    Low-temperature (season) set - used for the operation of the air conditioner in cooling mode at low ambient temperatures (usually provided in the air conditioner as an optional feature). The kit includes: the controller of the outdoor unit fan motor, compressor crankcase heater and heater drain line.

    In some series of inverter split systems this option is implemented in hardware and software, thus if there is a need to use the air conditioner in the winter for cooling, you must install only drain the heater.

    The Indoor Unit

    Model Name
    MCD-60HRFN1
    Power Options, V/Hz/Ph
    220/50/1

    Power, kW

    Cooling Power
    4.980
    ... 18.460
    Heating Capacity
    5.280
    ... 20.510

    Power consumption, kW

    Cooling
    1.660
    ... 7.100
    Heating
    1.760
    ... 7.320
    Air flow rate, m³/h
    1,900
    ... 1,450
    Noise level, dB
    52.00
    ... 46.00
    Drain pipes diameter, mm
    32 mm

    Panel

    Panels Colour
    White
    Panel Size (WxHxD), mm
    950
    x 55
    x 950
    Panel Weight, kg
    5.00

    Dimensions(WxHxD), mm

    Without Package
    840
    x 287
    x 840
    in Multiples
    900
    x 292
    x 900

    Weight, kg

    Net Weight
    31.00
    Gross Weight
    34.00

    The outdoor Unit

    Model Name
    MOE30U-60HFN1-S
    Compressors Type
    Inverter
    Compressor
    GMCC ROTARY

    Freon

    Freon Type
    R410A
    Freon Weight, kg
    4.30, kg
    Power Options, V/Hz/Ph
    380/50/3
    Air flow rate, m3/h
    7,500
    Noise level, dB
    63.00

    Diameter Pipes, mm

    Liquid
    9.52
    Gas
    15.90
    Max length of main line, m
    65
    Max vertical drop, m
    30

    Dimensions(WxHxD), mm

    Without Package
    952
    x 1333
    x 410
    in Multiples
    1095
    x 1470
    x 500

    Weight, kg

    Net Weight
    113.00
    Gross Weight
    126.00