Main functions
Operating ambient temperatures
In 2017 model line LCAC DC-inverter Midea, successfully passed the test for compliance with a number of technical prameters, according to Eurovent standards.
This fact confirms the high quality of the products and full compliance with the expectations of customers all over the world, as the company produces air conditioners for all major world markets, offers sales and service support through its distribution network on all continents. Only the most famous and popular world manufacturers of air conditioners provided their products for certification in the laboratory Eurovent, which carefully analyze a range of characteristics and conduct critical test kits for compliance with the declared factory parameters of devices.
Data on products certified by Eurovent are available for viewing on the Internet at: www.eurovent-certification.com
Technology
Blue Fin
Blue fin heat exchanger cover - Protection against corrosion. Special anti-corrosion coating of the heat exchanger, protection from atmospheric phenomena and effects of aggressive environment. May differ in color (have blue, green, gold or no color at all (clear varnish)
Silence
The "Silence" - air conditioning reduces the fan speed of the indoor unit to a minimum, with the noise of the air conditioner as well reduced.
Sine-Wave Inverter
Technology 180° -gradusnogo wave inverter conversion - control voltage without the "pulse" effects (jagged sinusoid).
Compared with the current standard of 120° rectangular wave has the following advantages:
- Ability to work with a wider range of supply voltage and frequency.
- Most of the energy efficiency and energy conservation.
- More soft start, lower noise and vibration.
- more control.
The Ionizer
Air purification system is provided with a high-efficiency air conditioner ionizer that produces millions of negative ions that neutralize all the harmful elements present in your home. Negatively charged ions attract the dust particles, bacteria, mold spores and viruses, neutralize them, supporting chichtotu and freshness of the air in the room.
The ionizer is usually located on the left side of the housing of the indoor unit under the blinds (see photo below). On some series of domestic and semi-industrial split systems, it can be installed optionally)
Aluminium heat exchanger with hydrophilic coating
Improved wettability of the heat exchanger aluminum plates which have a special coating with a hydrophilic layer, ensuring rapid removal of condensate from the indoor unit that does not allow to quickly form of mold and bacteria, providing a more efficient operation of the air conditioner.
Refrigerant Leakage Detect
Its a electronical function of Main PCB and self-diagnostic system into AC.
When pipe-temperature sensor at inlet line of evaporator will indicate highest temperature, system will indicate "EC" code in a display of indoor units, its mean "ask for service centre for visit maintance team with leakage detectors and tools"
Outdoor unit design "Brilliant"
Designers Midea did not forget about the exterior of the exterior unit of the air conditioner, which in itself is a rarity for climate technology. The outdoor unit is much more elegant than its counterparts, it has facets like a diamond, and attention to detail speaks of a high level of production and a carefully thought-out design concept.
Compresor DC inverter
Compressor with inverter DC can increase the efficiency of the air conditioner, thus reducing power consumption saves your costs. This system is much more economical and safer than air conditioners with a constant output of the compressor.
Wi-Fi Control (Wi-Fi stick)
Mission's Wi-Fi and Smart Kits* are designed for even more comfortable and easy operation (for some series of Wi-Fi stick - option).
Customers can download absolutely free app for your smartphone with the QR-code located in the user's manual.
360°Air Flow Panel
With the 360°air flow panel, the air can be distributed to every corner of the room.
Motor DC inverter indoor unit
The indoor unit is used to rotate the impeller DC - motor. This can significantly reduce noise and power consumption. And also get 12 positions change the speed of the impeller.
DC inverter motor Outdoor Unit
In outdoor units, a DC motor is used to rotate the fan. This allows you to significantly reduce noise and power consumption. And also get several positions of the fan speed, depending on the needs of the system.
Night Mode
Mode is activated with the remote control and provides a comfortable environment for a peaceful and deep sleep during the 7-hour cycle with a temperature change of reference values, as well as setting the minimum noise level and economical energy consumption. After that, the temperature returns to the originally specified value.
Redirecting the flow of air to neighboring rooms using air ducts
With the help of air ducts, it is possible to organize the redirection of part of the treated air flow to neighboring rooms.
Dry Mode
Dry mode automatically selects cooling, based on the difference between fixed and temparaturoy actual room temperature. The temperature is regulated while reducing humidity repeated switching on and off of the cooling and ventilation only. when the dry mode on the remote control shows "Drop"
Temperature compensation
The function of temperature compensation corrects the temperature in the person's zone of being comfortable, (because the air temperature near the floor and ceiling can differ by several degrees) by further increasing / decreasing the temperature from the value set from the remote control. Thus, compensation and equalization of the overall room temperature occurs. For household split systems, the value is set by the manufacturer and is 2°C.
Multi-Bend Heat Exchanger
Increased heat. This unit uses the heat exchangers with tubes of a special design, the inner surface of which has trapezoidal notches "Innergrove cooper", which provides maximum heat transfer surface area increased. Due to this heat increases by 28%, reduced power consumption, and hence increases the efficiency of the system.
Full-DC (3D DC-inverter)
All engines compressors and fans in the system are made by DC-inverter technology.
Low Ambient Cooling
Low-temperature (season) set - used for the operation of the air conditioner in cooling mode at low ambient temperatures (usually provided in the air conditioner as an optional feature). The kit includes: the controller of the outdoor unit fan motor, compressor crankcase heater and heater drain line.
In some series of inverter split systems this option is implemented in hardware and software, thus if there is a need to use the air conditioner in the winter for cooling, you must install only drain the heater.
Reserved ON-OFF and Alarm Ports
ON-OFF Switch: With the reserved ports, a remote switch can be easily connected to a realize remote control. Alarm Port: The built-in PCB can output alarm signal, which makes setting up an external alarm light or vibration gauge possible.
Specifications
The Indoor Unit
Power, kW
Power consumption, kW
Energy Efficiency Class
Energy Efficiency Ratio
Diameter Pipes, mm
Panel
Dimensions(WxHxD), mm
Weight, kg
The outdoor Unit
Freon
Diameter Pipes, mm
Dimensions(WxHxD), mm
Weight, kg
Video
Soft Midea AIR Setup Wi-Fi
Soft Midea AIR Setup Wi-Fi