Midea "M4OB-36HFN8-Q" series

Suggested retail price

81,590-hrv.

    Outdoor units of multi-split systems are available in 5 standard sizes and allow you to create the optimal configuration for each specific facility, along with various types and models of indoor units.
    Systems with four indoor units are equipped with reliable DC-inverter compressors with reduced noise levels and a wide range of compressor speed adjustment. To effectively control the operation of the system, an original and reliable algorithm was used to coordinate the operation of the compressor, fan motor and electronic expansion valves.

    Outdoor model M4OB-36HFN8-Q
    Indoor unit combination MSAFBU-09HRDN8-QRD0GW
    Power Supply (Outdoor)V-Ph-Hz220~240-1-50
    CoolingCapacityBtu/h36000(12430~37000)
    InputW3300(330~4250)
    Rated currentA15.0(1.5~18.5)
    EERW/W3.2
    HeatingCapacityBtu/h37000(9730~41000)
    InputW2760(470~4210)
    Rated currentA12.1(2.1~18.4)
    COPW/W3.93
    Max. input consumptionW4600
    Max. currentA21.5
    CompressorModel KTF310D43UMT
    Type ROTARY
    Brand GMCC
    CapacityBtu/h10010
    InputW2765
    Rated current(RLA)A5.38
    Locked rotor Amp(LRA)A/
    Thermal protector position EXTERNAL
    CapacitorμF/
    Refrigerant oilmlVG74/1000
    Outdoor fan motorModel ZKFN-120-8-2
    Qty 1
    OutputW120
    CapacitoruF/
    Speedr/min900/750/600
    Outdoor coilNumber of rows 2.0
    Tube pitch(a)x row pitch(b)mm25.4x22
    Fin spacingmm1.3
    Fin type (code) Hydrophilic aluminum
    Tube outside dia.and typemmΦ9.52,Inner groove tube
    Coil length x height x widthmm995x762x44
    Number of circuits 4
    Outdoor air flowm3/h4000
    Outdoor sound pressure leveldB(A)61
    Outdoor sound power leveldB(A)67
    Throttle type EXV+Capillary
    Outdoor unitDimension(W*D*H)mm946x410x810
    Packing (W*D*H)mm1090x500x885
    Net/Gross weightKg68.8/75.6
    Refrigerant typeType-R32
    GWP-675
    Charged quantityKg2.1
    Design pressureMPa4.3/1.7
    Refrigerant pipingLiquid side/ Gas sidemm(inch)4 x Φ6.35/3x Φ9.52
    +1xΦ12.7(4x1/4”/3x3/8”+1x1/2”)
    Max. length for all roomsm80
    Max. length for one iDUm35
    Max. height difference between IDU and ODUm15
    Max. height difference between IDUm10
    Ambient tempCooling°C-15~50
    Heating°C-15~24
      
    Notes: 
    1) Capacities are based on the following conditions: 
    Cooling(T1): - Indoor Temperature 27°C(80.6°F) DB /19 °C(66.2°F) WB      
    -Outdoor Temperature 35 °C(95°F) DB /24 °C(75.2°F) WB 
    -Interconnecting Piping Length 5m 
    - Level Difference of Zero. 
      
    Heating: - Indoor Temperature 20°C(68°F) DB / 15°C(59°F) WB 
    -Outdoor Temperature 7°C(44.6°F) DB / 6°C(42.8°F) WB 
    - Interconnecting Piping Length 5 m 
    - Level Difference of Zero. 
      
    2) Capacities are Net Capacities. 
    3) Due to our policy of innovation some specifications may be changed without notification. 
    4)For other combination, refer to the combination table.