Operating ambient temperatures
Suggested retail price
Energy Efficiency
Technology
5 Grades Outdoor Fan Speeds
By utilising DC fan motors on the outdoor unit, has upgraded the fan speeds from 2 speeds to 5 speeds. This also too contributes to energy saving and again, more control over outdoor fan airflow- generated sound levels.
Sine-Wave Inverter
Technology 180° -gradusnogo wave inverter conversion - control voltage without the "pulse" effects (jagged sinusoid).
Compared with the current standard of 120° rectangular wave has the following advantages:
- Ability to work with a wider range of supply voltage and frequency.
- Most of the energy efficiency and energy conservation.
- More soft start, lower noise and vibration.
- more control.
Aluminium heat exchanger with hydrophilic coating
Improved wettability of the heat exchanger aluminum plates which have a special coating with a hydrophilic layer, ensuring rapid removal of condensate from the indoor unit that does not allow to quickly form of mold and bacteria, providing a more efficient operation of the air conditioner.
Outdoor unit design "Brilliant"
Designers Midea did not forget about the exterior of the exterior unit of the air conditioner, which in itself is a rarity for climate technology. The outdoor unit is much more elegant than its counterparts, it has facets like a diamond, and attention to detail speaks of a high level of production and a carefully thought-out design concept.
Compresor DC inverter
Compressor with inverter DC can increase the efficiency of the air conditioner, thus reducing power consumption saves your costs. This system is much more economical and safer than air conditioners with a constant output of the compressor.
DC inverter motor Outdoor Unit
In outdoor units, a DC motor is used to rotate the fan. This allows you to significantly reduce noise and power consumption. And also get several positions of the fan speed, depending on the needs of the system.
Multi-Bend Heat Exchanger
Increased heat. This unit uses the heat exchangers with tubes of a special design, the inner surface of which has trapezoidal notches "Innergrove cooper", which provides maximum heat transfer surface area increased. Due to this heat increases by 28%, reduced power consumption, and hence increases the efficiency of the system.
Low Ambient Cooling
Low-temperature (season) set - used for the operation of the air conditioner in cooling mode at low ambient temperatures (usually provided in the air conditioner as an optional feature). The kit includes: the controller of the outdoor unit fan motor, compressor crankcase heater and heater drain line.
In some series of inverter split systems this option is implemented in hardware and software, thus if there is a need to use the air conditioner in the winter for cooling, you must install only drain the heater.
Description
Outdoor units multi-split systems, DC-Inverter manufactured in 5 sizes and allow you to create the best for each individual object set, together with a variety of types and models of indoor units.
Multisystem Midea DC-Inverter are characterized by high energy efficiency, power index HRFN1 (Full DC) have Time for details SCOP / SEER> 3.6, the exact adjustment of the room temperature, increased efficiency at part load - refrigerant from a compressor with variable power is switched on the system internal blocks electronic control valves (EXV) of the outdoor unit and the control signals from the microprocessor of each internal.
This series of multi-split systems can be used in apartments, houses, offices and shops, and hotels and other small objects that have restrictions on the placement of a large group of outdoor units on the facade, the roof, the balcony.
The systems use ozone-safe refrigerant R-410.
Specifications
Outdoor Model | M2OE-14HFN1-Q | |||
Outdoor Model NEW | M2O-14FN1-Q | |||
Indoor unit combination | Single | MA-07N1D0-I MSMAAU-07HRDN1 |
||
Power supply | V,Hz,Ph | 220-240V,50Hz, 1Ph | ||
Cooling | Capacity | Btu/h | 7000-14000 | 14000 |
Input | W | 660-1250 | 1200 | |
Rated current | A | 2.9-5.4 | 5,2 | |
Heating | Capacity | Btu/h | 8000-15000 | 15000 |
Input | W | 620-1280 | 1160 | |
Rated current | A | 2.7-5.6 | 5 | |
Seasonal Cooling | Pdesignc | kW | 4.1 | |
SEER | W/W | 6,8 | ||
Energy Efficiency Class | A++ | |||
Heating(Average) | Pdesignh | kW | 3.4 | |
SCOP | W/W | 4.0 | ||
Energy Efficiency Class | A+ | |||
Tbiv | ℃ | -7 | ||
Tol | ℃ | -15 | ||
Max. input consumption | W | 2000 | ||
Max. input current | A | 11 | ||
Compressor | Model | ASN108D22UEZ | ||
Type | ROTARY | |||
Brand | GMCC | |||
Capacity | Btu/h | 10987 | ||
Input | W | 825 | ||
Rated current(RLA) | A | 5,8 | ||
Refrigerant oil | ml | ESTER OIL VG74 370 | ||
Outdoor fan motor | New Model | ZKFN-40-8-1L | ||
Model | ||||
Qty | 40(Output) | |||
Speed(Hi/Med/Lo) | r/min | 810 | ||
Outdoor coil | Number of rows | 1 | ||
Tube pitch(a)* row pitch(b) | mm | 21x13.37 | ||
Fin spacing | mm | 1.2 | ||
Fin type | Hydrophilic aluminium | |||
Tube outside dia.and type | mm | Φ7,innergroove tube | ||
Coil length * height * width | mm | 870x504x13.37 | ||
Number of circuits | 2 | |||
Outdoor air flow | m3/h | 2100 | ||
Indoor sound power level | dB(A) | 52 | ||
Outdoor sound pressure level | dB(A) | 54 | ||
Outdoor sound power level | dB(A) | 60 | ||
Throttle type | Capillary+EXV | |||
Outdoor unit | Dimension(WxDxH) | mm | 800x333x554 | |
Packing(WxDxH) | mm | 920x390x615 | ||
Net/Gross weight | kg | 30.5/33.5 | ||
Refrigerant | Type | R410A | ||
GWP | 2088 | |||
Charged quantity | Kg | 1.25 | ||
Design pressure | MPa | 4.2/1.5 | ||
Refrigerant piping | Liquid side/ Gas side | mm (inch) | 2 x Φ6.35/Φ9.52(1/4"/3/8") | |
Max. length for all rooms | m | 40 | ||
Max. length for one indoor unit | m | 25 | ||
Max. height difference between indoor and outdoor unit | m | 15 | ||
Max. height difference between indoor units | m | 10 | ||
Ambient temperature | Cooling | ℃ | -15-50 | |
Heating | ℃ | -15-24 | ||
Remarks: | ||||
1.The above design and specifications are subject to change without prior notice for product improvement. | ||||
2.The values given in the table for the noise level reflect the levels in hemi-anechoic rooms. |