Suggested retail price
Technology
Wired remote control for indoor unit
The internal block is completed / can be completed (option) with the wire control panel.
General functional features:
- Connection to indoor units using stranded wire.
- The job modes.3. Set the fan speed.
- Display information about operating modes on the LCD.
- Setting the time of automatic on / off using a timer.
Description
VENTILATION Recuperators series CE-HRV together with the air conditioning and VRF systems provide perfectly comfortable indoor climate by changing the temperature and humidity of incoming fresh air, depending on the climatic conditions inside and outside the premises.
Features of this series:
- There are several modes of operation
- Provides a highly efficient heat exchange between the supply and exhaust air
- The control system individually or as part of a central control system VRF Midea. Possible to organize group control
- The compact design and low noise level
As a heat exchanger, a specially developed recuperator made of HEP material (multilayer paper with special processing and varnish-protective coating) is used. It is optimized compared to 2006-08 models.
also fan design.
- Dimensions and volume of installations are reduced on average by 27% compared to 2006-08 models;
- The weight of the plants has also decreased, which, combined with a reduction in size, makes installation and maintenance of systems easier and more convenient.
Fresh air from outside passes through the heat exchanger of the special paper, is heated or cooled (depending on season) due to the thermal energy of the exhaust air. The process of heat exchange occurs between air currents moving in sync.
The heat exchanger is due to its design, provides:
- Otlichnye ability to transfer heat and moisture of heat transfer coefficient reaches a value of 74% (see. The specification for each type ventustanovoki).
- Good fire safety parameters (antivozgoraemost), which ensures the operation of the fan unit larger safety and applicability.
- Excellent parameters capture condensate drops, the material is resistant to wear and suitable for long-term operation.
In some cases, it is necessary to provide a “fresh air” in the room - the picture shows the scheme when the “excess” of supply air is supplied to the common area, and is removed through adjacent rooms, where it enters through overflow grids or natural leaks in the structure.
For some objects, for example, medical ones, it is important to provide excess “vacuum” of air in the working area - the picture shows a diagram when the main volume of air with bacteria must be removed from the working area under the ceiling, and the air flow is supplied both to the common area and to adjacent rooms through other devices, this air enters the working area through the transfer grates.
Specifications
Model |
CE-HRV-200 |
CE-HRV-300 |
CE-HRV-400 |
CE-HRV-500 |
CE-HRV-800 |
|||
Air flow (m3 / h) |
200 |
300 |
400 |
500 |
800 |
|||
Static pressure (Pa) |
75 |
75 |
80 |
80 |
100 |
|||
In summer, air-conditioning mode - Cooling (t outdoor > t room) |
Temperature heat transfer efficiency(%) |
60 |
60 |
60 |
60 |
60 |
||
Enthalpy heat exchange efficiency(%) |
50 |
50 |
50 |
50 |
50 |
|||
In winter air-conditioning mode - Heating (t outdoor < t room) |
Temperature heat transfer efficiency(%) |
65 |
65 |
65 |
70 |
70 |
||
Enthalpy heat exchange efficiency(%) |
55 |
55 |
60 |
60 |
60 |
|||
Power supply (V-Hz-F) |
220~240-1-50 |
|||||||
Fan motor |
type |
Single-phase asynchronous |
||||||
Power Consumption (W) |
20 |
40 |
80 |
120 |
360 |
|||
Operating Current (A) |
0.5 |
0.56 |
1 |
1.2 |
2 |
|||
Dimensions (L * W * H) mm |
666*580*264 |
744*599*270 |
744*804*270 |
824*904*270 |
1116*884*388 |
|||
Net / Gross Weight (kg) |
22/46 |
23/48 |
30/57 |
35.5/65.5 |
57.5/91.5 |
|||
Sound pressure level dB(A) |
27 |
30 |
32 |
35 |
39 |
|||
Wired Remote Control |
KJR-27B/E |
Model |
CE-HRV-1000 |
CE-HRV-1500 |
CE-HRV-2000 |
||
Air flow (m3 / h) |
1500 |
1500 |
2000 |
||
Static pressure (Pa) |
150 |
160 |
170 |
||
In summer, air-conditioning mode - Cooling (t outdoor > t room) |
Temperature heat transfer efficiency (%) |
60 |
60 |
60 |
|
Enthalpy heat exchange efficiency (%) |
50 |
50 |
50 |
||
In winter air-conditioning mode - Heating (t outdoor < t room) |
Temperature heat transfer efficiency (%) |
70 |
70 |
70 |
|
Enthalpy heat exchange efficiency (%) |
60 |
60 |
60 |
||
Power supply (V-Hz-F) |
220~240-1-50 |
380-3-50 |
|||
Fan motor |
type |
Single-phase asynchronous |
Three-phase asynchronous |
||
Power Consumption (W) |
360 |
900 |
1100 |
||
Operating Current (A) |
2.4 |
3.2 |
3.6 |
||
Dimensions (L * W * H) mm |
1116*1134*388 |
1500*1200*540 |
1500*1200*540 |
||
Net / Gross Weight (kg) |
59/95 |
160/200 |
175/215 |
||
Sound pressure level dB(A) |
40 |
51 |
53 |
||
Wired Remote Control |
KJR-27B/E |