0-hrv.

    Wired consoles are designed for mounting on the walls of the room and are connected to the indoor unit of the air conditioner by means of a wire, allow controlling the air conditioners from long distances, they can receive a signal from the IR remote control, have a built-in temperature sensor, plan the parameters of the system for a week, etc.

    KJR-10B & KJR-12B

    • The built-in daily timer offers automatically starts and stops the system at set times based on user needs.
    • The FOLLOW ME function enables the wired controller to detect the air temperature at the user's height instead of the ceiling or floor for accurate temperature configuration.
    • The wired controller conveniently connects to the indoor unit's display panel via connecting wire.
    • The address setting function is coupled with easy installation and simple future maintenance. Service personnel can set the address for the indoor unit using KJR-10B

    KJR-86C & KJR-29B & KJR-90C

    • Clean Filter Reminder - The wired controller records the total running time of the indoor unit.
    • When the accumulated running time reaches the pre-set value, the system will remind users to clean the indoor unit's filter. Cleaning the filter regularly keep indoor air fresh, clean and good for your health.
    • Silent Mode - In cooling, heating and auto mode, operating silent mode can lower running noise by setting the fan speed to low for a quieter environment.
    • Keyboard Locking - The locking function can be used to prevent other people from using the controller.
    • Remote Signal Receiving Function. KJR-29B and KJR-90C provide a signal receiver for the remote controller. Signals from the remote control can be received by a wired controller, then sent to the indoor unit for easy control.

    • The FOLLOW ME function enables the wired controller to detect the air temperature at the user's height instead of the ceiling or floor for accurate temperature configuration. The wired controller conveniently connects to the indoor unit's display panel via connecting wire.

    • The address setting function is coupled with easy installation and simple future maintenance. Service personnel can set the address for the indoor unit using KJR-29B and KJR-90C.

    • One-key 26°C. KJR-86C has a one-key 26°C function. For saving energy and remaining comfortable, 26°C is the ideal temperature.

    • User Friendly Design. KJR-86C is a hidden mode controller specially designed for hotels, hospitals, schools and other similar types of buildings. Hidden mode key controller: Press the temperature buttons "+" and "-" simultaneously for 3 seconds to select the operation mode: COOL or HEAT.

    • User Friendly Installation. The background light function makes it easy to use in the dark. As small as an electric switch, the installation effect more attractive.
    • Auto Restart Function. If the power fails, the system records running parameters such as: ON/OFF state, mode, Fan speed, Temperature, Swing and Locking status. When powered on again, the system automatically checks the status before the failure.

    KJR-120B*

    * KJR-120B is compatible with the 2-pipe system. In auto mode, it only can run in cooling mode.

    • Auto mode is specially designed for the V4 plus R series In auto mode, the V4 plus R system can automatically switch between COOL or HEAT mode according to the temperature difference between Tf (indoor temperature) and Ts (setting temperature). 
    • If a malfunction occurs, the temperature setting display area will show the error code. The error status can be checked easily on the indoor unit's wired controller.
    • The wired controller records the total running time of the indoor unit. When the accumulated running time reaches the pre-set value, it will remind you to clean the air filter. Cleaning the filter regularly keeps the indoor air fresh and clean, and is good for your health.
    • In cooling, heating, and auto mode, silent mode reduces the running noise by setting the fan speed to low so you can enjoy peace and quiet while remaining comfortable.

    KJR-120C

    • Weekly schedule wired controller can query the indoor temperature and the set parameters of the weekly schedule. It can show the error codes and running state of the indoor unit. The LCD backlight enables users to operate the device in the dark.
    • The weekly schedule timer function allows users to set up to four scheduled periods per day for frequent adjustments. The Schedule feature allows you to program device behavior. If a device must follow a certain schedule, you can program the device to operate only at the scheduled times. Scheduled devices do not activate unless programmed to do so. They are centrally managed, significantly reducing energy consumption.
    • This function is specifically designed for people who work overtime. Pressing the Delay button postpones system shutdown by 1
    • or 2 hours.
    • If a malfunction occurs, the temperature setting display area will show the error code. The error status can be checked easily on the indoor unit's wired controller.
    • Press the left-right and up-down buttons simultaneously for three seconds to switch between °F and °C.

    KJR-90A

    • Selecting the operating modes: AUTO, COOL, DRY, HEAT, FAN
    • Setting the temperature
    • Ability to set the on / off timer by time
    • Fan speed selection: "AUTO", "LOW", "MED", "HIGH"
    • Control of the operation of blinds (Swing)