Operating ambient temperatures
Suggested retail price
Technology
Aluminium heat exchanger with hydrophilic coating
Improved wettability of the heat exchanger aluminum plates which have a special coating with a hydrophilic layer, ensuring rapid removal of condensate from the indoor unit that does not allow to quickly form of mold and bacteria, providing a more efficient operation of the air conditioner.
Compresor DC inverter
Compressor with inverter DC can increase the efficiency of the air conditioner, thus reducing power consumption saves your costs. This system is much more economical and safer than air conditioners with a constant output of the compressor.
Low Ambient Cooling
Low-temperature (season) set - used for the operation of the air conditioner in cooling mode at low ambient temperatures (usually provided in the air conditioner as an optional feature). The kit includes: the controller of the outdoor unit fan motor, compressor crankcase heater and heater drain line.
In some series of inverter split systems this option is implemented in hardware and software, thus if there is a need to use the air conditioner in the winter for cooling, you must install only drain the heater.
Multi-Bend Heat Exchanger
Increased heat. This unit uses the heat exchangers with tubes of a special design, the inner surface of which has trapezoidal notches "Innergrove cooper", which provides maximum heat transfer surface area increased. Due to this heat increases by 28%, reduced power consumption, and hence increases the efficiency of the system.
Full-DC (3D DC-inverter)
All engines compressors and fans in the system are made by DC-inverter technology.
Sine-Wave Inverter
Technology 180° -gradusnogo wave inverter conversion - control voltage without the "pulse" effects (jagged sinusoid).
Compared with the current standard of 120° rectangular wave has the following advantages:
- Ability to work with a wider range of supply voltage and frequency.
- Most of the energy efficiency and energy conservation.
- More soft start, lower noise and vibration.
- more control.
Description
The new generation VRF V4 Plus R (Heat Recovery) systems belong to the elite air conditioning systems with the highest level of comfort. In the lineup there are 5 base units with a capacity of 8, 10, 12, 14, 16 HP, which can be combined into a system of 1-4 blocks with a total capacity of up to 64 HP with a change step of 2 HP. A feature of VRF V4 Plus R is their ability to provide heating of one zone while cooling another. This is achieved through the use of MS distribution blocks placed between the outdoor units (connection is made by three pipes) and indoor units. The MS-unit distributes the refrigerant between indoor units operating in different modes - while one part works for heating, and the other, at the same time, for cooling. The energy efficiency in this system compared with double-tube heat-cold systems is much higher. The energy efficiency indicator in heating operation mode (COP) can reach a value of 7.0. A maximum of 64 indoor units can be connected to the system.
Specifications
Video
VRF V4 Plus R series Heat Recovery
V4 Plus R (Heat Recovery) systems of the new generation belong to the elite VRF air conditioning systems with the highest level of comfort.