Suggested retail price
Technology
Sine-Wave Inverter
Technology 180° -gradusnogo wave inverter conversion - control voltage without the "pulse" effects (jagged sinusoid).
Compared with the current standard of 120° rectangular wave has the following advantages:
- Ability to work with a wider range of supply voltage and frequency.
- Most of the energy efficiency and energy conservation.
- More soft start, lower noise and vibration.
- more control.
Aluminium heat exchanger with hydrophilic coating
Improved wettability of the heat exchanger aluminum plates which have a special coating with a hydrophilic layer, ensuring rapid removal of condensate from the indoor unit that does not allow to quickly form of mold and bacteria, providing a more efficient operation of the air conditioner.
Outdoor unit design "Brilliant"
Designers Midea did not forget about the exterior of the exterior unit of the air conditioner, which in itself is a rarity for climate technology. The outdoor unit is much more elegant than its counterparts, it has facets like a diamond, and attention to detail speaks of a high level of production and a carefully thought-out design concept.
DC inverter motor Outdoor Unit
In outdoor units, a DC motor is used to rotate the fan. This allows you to significantly reduce noise and power consumption. And also get several positions of the fan speed, depending on the needs of the system.
Multi-Bend Heat Exchanger
Increased heat. This unit uses the heat exchangers with tubes of a special design, the inner surface of which has trapezoidal notches "Innergrove cooper", which provides maximum heat transfer surface area increased. Due to this heat increases by 28%, reduced power consumption, and hence increases the efficiency of the system.
Description
- 6 basic outdoor units, it is allowed to combine in 2- and 3-module assemblies (up to 168 kW).
- The use of outdoor units of the VRF V6 HR series allows organizing the simultaneous operation of indoor units for heating and cold
- The range of outdoor temperatures:
- for cooling: –15 ° C ~ + 52 ° C;
- for heating: –25 ° C ~ + 19 ° C;
- for DHW preparation: –20 ° C ~ + 43 ° C.
- In this series, it is possible to use hydronic modules with a power of 14 kW, which use part of the excess heat to heat hot water.
- To connect indoor units, recuperation units are used. These units switch the refrigerant supplied and returned from each indoor unit, taking into account the selected operating mode and temperature parameters. In the MS recuperation units, the freon flows are redistributed, which allows the indoor units to operate in different modes at the same time.
- The connection of indoor units to MS units is two-pipe, and the connection of MS units to the general line of the system (to the outdoor block) - three-pipe.
- It is important to use such systems when there is an excess of heat (cold) in some of the serviced premises, while in others there is a shortage (for example, premises oriented in different cardinal points, data centers).
Specifications
HP | 8 | 10 | 12 | ||
Model name | MV6-R252WV2GN1 | MV6-R280WV2GN1 | MV6-R335WV2GN1 | ||
Power supply | V/N/Hz | 380-415/3/50(60) | |||
Cooling1 | Capacity | kW | 22.4 | 28 | 33.5 |
Power input | kW | 5.25 | 7.18 | 8.64 | |
EER | 4.27 | 3.90 | 3.88 | ||
Heating2(Rated) | Capacity | kW | 22.4 | 28 | 33.5 |
Power input | kW | 3.96 | 5.46 | 6.57 | |
COP | 5.66 | 5.13 | 5.10 | ||
Heating2(Max) | Capacity | kW | 25 | 31.5 | 37.5 |
Power input | kW | 4.69 | 7.12 | 9.48 | |
COP | 5.33 | 4.43 | 3.95 | ||
Connected indoor unit | Total capacity | 50-200% of outdoor unit capacity3 | |||
Maximum quantity | 64 | 64 | 64 | ||
Compressor | Type | DC inverter | |||
Quantity | 1 | ||||
Oil type | FV68H | ||||
Start-up method | Soft start | ||||
Fan | Type | Propeller | |||
Motor type | DC | ||||
Quantity | 1 | ||||
Motor output | kW | 0.92 | 0.92 | 0.92 | |
Static pressure | Pa | 0,20,40,60,80(Selectable) | |||
Air flow rate | m3/h | 9000 | 9500 | 10000 | |
Drive type | Direct | ||||
Refrigerant | Type | R410A | |||
Factory charge | kg | 8 | 8 | 8 | |
Pipe connections4 | Liquid pipe | mm | Φ12.7 | Φ12.7 | Φ12.7 |
Low pressure gas pipe | mm | Φ25.4 | Φ25.4 | Φ25.4 | |
High pressure gas pipe | mm | Φ19.1 | Φ19.1 | Φ19.1 | |
Sound pressure level5 | dB(A) | 58 | 58 | 60 | |
Sound power level5 | dB(A) | 78 | 78 | 81 | |
Net dimensions (W×H×D) | mm | 990×1635×790 | 990×1635×790 | 990×1635×790 | |
Packed dimensions (W×H×D) | mm | 1090×1805×860 | 1090×1805×860 | 1090×1805×860 | |
Net weight | kg | 232 | 232 | 232 | |
Gross weight | kg | 248 | 248 | 248 | |
Ambient temp. operation range | Cooling6 | oC(DB) | -15 ~ 52 | ||
Heating | oC(WB) | -25 ~ 19 | |||
Domestic hot water | oC(DB) | -20 ~ 43 | |||
Notes: | |||||
1. Indoor air temperature 27°C DB, 19°C WB; outdoor air temperature 35°C DB; equivalent refrigerant piping length 7.5m with zero level difference. | |||||
2. Indoor air temperature 20°C DB; outdoor air temperature 7°C DB, 6°C WB; equivalent refrigerant piping length 7.5m with zero level difference. | |||||
3. Refer to table 1-5.1: Indoor and outdoor unit combination ratio limitations in Part 1. | |||||
4. Diameters given are those of the unit's stop valve. | |||||
5. Sound pressure level is measured at a position 1m in front of the unit and 1.3m above the floor in a semi-anechoic chamber. | |||||
6. -15°C to -5°C low temperature cooling operation is just available for MS01. |
HP | 14 | 16 | 18 | 20 | ||
Model name | MV6- R400WV2GN1 | MV6- R450WV2GN1 | MV6- R500WV2GN1 | MV6- R560WV2GN1 | ||
Power supply | V/N/H | 380-415/3/50(60) | ||||
Cooling1 | Capacity | kW | 40 | 45 | 50 | 56 |
Power input | kW | 9.83 | 12.00 | 13.81 | 17.39 | |
EER | 4.07 | 3.75 | 3.62 | 3.22 | ||
Heating2(Rated) | Capacity | kW | 40 | 45 | 50 | 56 |
Power input | kW | 8.26 | 9.78 | 11.90 | 14.77 | |
COP | 4.84 | 4.60 | 4.20 | 3.79 | ||
Heating2(Max) | Capacity | kW | 45 | 50 | 56 | 63 |
Power input | kW | 9.78 | 12.26 | 14.77 | 18.33 | |
COP | 4.60 | 4.08 | 3.79 | 3.44 | ||
Connected indoor unit |
Total capacity | 50-200% of outdoor unit capacity3 | ||||
Maximum quantity | 64 | 64 | 64 | 64 | ||
Compressor | Type | DC inverter | ||||
Quantity | 1 | |||||
Oil type | FV68H | |||||
Start-up method | Soft start | |||||
Fan | Type | Propeller | ||||
Motor type | DC | |||||
Quantity | 2 | |||||
Motor output | kW | 0.92×2 | 0.92×2 | 0.92×2 | 0.92×2 | |
Static pressure | Pa | 0,20,40,60,80(Selectable) | ||||
Air flow rate | m3/h | 14000 | 14900 | 15800 | 15800 | |
Drive type | Direct | |||||
Refrigerant | Type | R410A | ||||
Factory charge | kg | 10 | 10 | 10 | 10 | |
Pipe connections4 | Liquid pipe | mm | Φ15.9 | Φ15.9 | Φ15.9 | Φ15.9 |
Low pressure gas | mm | Φ28.6 | Φ28.6 | Φ28.6 | Φ28.6 | |
High pressure gas | mm | Φ22.2 | Φ22.2 | Φ22.2 | Φ22.2 | |
Sound pressure level5 | dB(A) | 61 | 64 | 65 | 65 | |
Sound power level5 | dB(A) | 81 | 88 | 88 | 88 | |
Net dimensions (W×H×D) | mm | 1340×1635×825 | 1340×1635×825 | 1340×1635×825 | 1340×1635×825 | |
Packed dimensions (W×H×D) | mm | 1405×1805×910 | 1405×1805×910 | 1405×1805×910 | 1405×1805×910 | |
Net weight | kg | 300 | 300 | 300 | 300 | |
Gross weight | kg | 325 | 325 | 325 | 325 | |
Ambient temp. operation range | Cooling6 | oC(DB) | -15 ~ 52 | |||
Heating | oC(WB) | -25 ~ 19 | ||||
Domestic hot water | oC(DB) | -20 ~ 43 | ||||
Notes: | ||||||
1. Indoor air temperature 27°C DB, 19°C WB; outdoor air temperature 35°C DB; equivalent refrigerant piping length 7.5m with zero level difference. | ||||||
2. Indoor air temperature 20°C DB; outdoor air temperature 7°C DB, 6°C WB; equivalent refrigerant piping length 7.5m with zero level difference. | ||||||
3. Refer to table 1-5.1: Indoor and outdoor unit combination ratio limitations in Part 1. | ||||||
4. Diameters given are those of the unit's stop valve. | ||||||
5. Sound pressure level is measured at a position 1m in front of the unit and 1.3m above the floor in a semi-anechoic chamber. | ||||||
6. -15°C to -5°C low temperature cooling operation is just available for MS01. |
HP | 22 | 24 | 26 | ||
Model name | MV6-R615WV2GN1 | MV6-R680WV2GN1 | MV6-R735WV2GN1 | ||
Combination type | 10HP+12HP | 10HP+14HP | 12HP+14HP | ||
Power supply | V/N/Hz | 380-415/3/50(60) | |||
Cooling1 | Capacity | kW | 61.5 | 68 | 73.5 |
Power input | kW | 15.82 | 17.01 | 18.46 | |
EER | 3.89 | 4.00 | 3.98 | ||
Heating2(Rated) | Capacity | kW | 61.5 | 68 | 73.5 |
Power input | kW | 12.03 | 13.72 | 14.83 | |
COP | 5.11 | 4.96 | 4.96 | ||
Heating2(Max) | Capacity | kW | 69.00 | 76.50 | 82.5 |
Power input | kW | 16.60 | 16.90 | 19.27 | |
COP | 4.16 | 4.53 | 4.28 | ||
Connected indoor unit |
Total capacity | 50-200% of outdoor unit capacity3 | |||
Maximum quantity | 64 | 64 | 64 | ||
Compressor | Type | DC inverter | |||
Quantity | 2 | ||||
Oil type | FV68H | ||||
Start-up method | Soft start | ||||
Fan | Type | Propeller | |||
Motor type | DC | ||||
Quantity | 2 | 2 | 3 | ||
Motor output | kW | 0.92×2 | 0.92×3 | 0.92×3 | |
Static pressure | Pa | 0,20,40,60,80(Selectable) | |||
Air flow rate | m3/h | 19500 | 23500 | 24000 | |
Drive type | Direct | ||||
Refrigerant | Type | R410A | |||
Factory charge | kg | 16 | 18 | 18 | |
Pipe connections4 | Liquid pipe | mm | Φ15.9 | Φ15.9 | Φ19.1 |
Low pressure gas | mm | Φ28.6 | Φ34.9 | Φ34.9 | |
High pressure gas | mm | Φ28.6 | Φ28.6 | Φ28.6 | |
Sound pressure level5 | dB(A) | 62 | 63 | 64 | |
Sound power level5 | dB(A) | 83 | 83 | 84 | |
Net dimensions (W×H×D) | mm | (990×1635×790)×2 | 990×1635×790+ 1340×1635×825 |
990×1635×790+ 1340×1635×825 |
|
Packed dimensions (W×H×D) | mm | (1090×1805×860)×2 | 1090×1805×860+ 1405×1805×910 |
1090×1805×860+ 1405×1805×910 |
|
Net weight | kg | 232×2 | 232+300 | 232+300 | |
Gross weight | kg | 248×2 | 248+325 | 248+325 | |
Ambient temp. operation range | Cooling6 | oC(DB) | -15 ~ 52 | ||
Heating | oC(WB) | -25 ~ 19 | |||
Domestic hot water | oC(DB) | -20 ~ 43 | |||
Notes: | |||||
1. Indoor air temperature 27°C DB, 19°C WB; outdoor air temperature 35°C DB; equivalent refrigerant piping length 7.5m with zero level difference. | |||||
2. Indoor air temperature 20°C DB; outdoor air temperature 7°C DB, 6°C WB; equivalent refrigerant piping length 7.5m with zero level difference. | |||||
3. Refer to table 1-5.1: Indoor and outdoor unit combination ratio limitations in Part 1. | |||||
4. Diameters given are those for the pipe connecting the outdoor unit combination to the first indoor branch joint for systems with total equivalent liquid piping lengths of less than 90m. For systems with total equivalent liquid piping lengths of 90m or longer, please refer to Part 3 “System Design and Installation” for connection piping diameters. | |||||
5. Sound pressure level is measured at a position 1m in front of the unit and 1.3m above the floor in a semi-anechoic chamber. | |||||
6. -15°C to -5°C low temperature cooling operation is just available for MS01. |
HP | 28 | 30 | 32 | ||
Model name | MV6-R785WV2GN1 | MV6-R835WV2GN1 | MV6-R900WV2GN1 | ||
Combination type | 12HP+16HP | 12HP+18HP | 16HP+16HP | ||
Power supply | V/N/Hz | 380-415/3/50(60) | |||
Cooling1 | Capacity | kW | 78.5 | 83.5 | 90 |
Power input | kW | 20.64 | 22.45 | 24.00 | |
EER | 3.80 | 3.72 | 3.75 | ||
Heating2(Rated) | Capacity | kW | 78.5 | 83.5 | 90 |
Power input | kW | 16.35 | 18.47 | 19.57 | |
COP | 4.80 | 4.52 | 4.60 | ||
Heating2(Max) | Capacity | kW | 87.5 | 93.5 | 100 |
Power input | kW | 21.74 | 24.25 | 24.52 | |
COP | 4.02 | 3.86 | 4.08 | ||
Connected indoor unit |
Total capacity | 50-200% of outdoor unit capacity3 | |||
Maximum quantity | 64 | 64 | 64 | ||
Compressor | Type | DC inverter | |||
Quantity | 2 | ||||
Oil type | FV68H | ||||
Start-up method | Soft start | ||||
Fan | Type | Propeller | |||
Motor type | DC | ||||
Quantity | 3 | 3 | 4 | ||
Motor output | kW | 0.92×3 | 0.92×3 | 0.92×4 | |
Static pressure | Pa | 0,20,40,60,80(Selectable) | |||
Air flow rate | m3/h | 24900 | 25800 | 29800 | |
Drive type | Direct | ||||
Refrigerant | Type | R410A | |||
Factory charge | kg | 18 | 18 | 20 | |
Pipe connections4 | Liquid pipe | mm | Φ19.1 | Φ19.1 | Φ19.1 |
Low pressure gas pipe | mm | Φ34.9 | Φ34.9 | Φ34.9 | |
High pressure gas pipe | mm | Φ28.6 | Φ28.6 | Φ28.6 | |
Sound pressure level5 | dB(A) | 65 | 66 | 67 | |
Sound power level5 | dB(A) | 89 | 89 | 91 | |
Net dimensions (W×H×D) | mm | 990×1635×790+ 1340×1635×825 |
990×1635×790+ 1340×1635×825 |
(1340×1635×825)×2 | |
Packed dimensions (W×H×D) | mm | 1090×1805×860+ 1405×1805×910 |
1090×1805×860+ 1405×1805×910 |
(1405×1805×910)×2 | |
Net weight | kg | 232+300 | 232+300 | 300×2 | |
Gross weight | kg | 248+325 | 248+325 | 325×2 | |
Ambient temp. operation range | Cooling6 | oC(DB) | -15 ~ 52 | ||
Heating | oC(WB) | -25 ~ 19 | |||
Domestic hot water | oC(DB) | -20 ~ 43 | |||
Notes: | |||||
1. Indoor air temperature 27°C DB, 19°C WB; outdoor air temperature 35°C DB; equivalent refrigerant piping length 7.5m with zero level difference. | |||||
2. Indoor air temperature 20°C DB; outdoor air temperature 7°C DB, 6°C WB; equivalent refrigerant piping length 7.5m with zero level difference. | |||||
3. Refer to table 1-5.1: Indoor and outdoor unit combination ratio limitations in Part 1. | |||||
4. Diameters given are those for the pipe connecting the outdoor unit combination to the first indoor branch joint for systems with total equivalent liquid piping lengths of less than 90m. For systems with total equivalent liquid piping lengths of 90m or longer, please refer to Part 3 “System Design and Installation” for connection piping diameters. | |||||
5. Sound pressure level is measured at a position 1m in front of the unit and 1.3m above the floor in a semi-anechoic chamber. | |||||
6. -15°C to -5°C low temperature cooling operation is just available for MS01. | |||||
HP | 34 | 36 | 38 | ||
Model name | MV6-R950WV2GN1 | MV6-R1000WV2GN1 | MV6-R1060WV2GN1 | ||
Combination type | 16HP+18HP | 18HP+18HP | 18HP+20HP | ||
Power supply | V/N/Hz | 380-415/3/50(60) | |||
Cooling1 | Capacity | kW | 95 | 100 | 106 |
Power input | kW | 25.81 | 27.62 | 31.20 | |
EER | 3.68 | 3.62 | 3.40 | ||
Heating2(Rated) | Capacity | kW | 95 | 100 | 106 |
Power input | kW | 21.69 | 23.81 | 26.67 | |
COP | 4.38 | 4.20 | 3.97 | ||
Heating2(Max) | Capacity | kW | 106 | 112 | 119 |
Power input | kW | 27.03 | 29.53 | 33.09 | |
COP | 3.92 | 3.79 | 3.60 | ||
Connected indoor unit |
Total capacity | 50-200% of outdoor unit capacity3 | |||
Maximum quantity | 64 | 64 | 64 | ||
Compressor | Type | DC inverter | |||
Quantity | 2 | ||||
Oil type | FV68H | ||||
Start-up method | Soft start | ||||
Fan | Type | Propeller | |||
Motor type | DC | ||||
Quantity | 4 | ||||
Motor output | kW | 0.92×4 | 0.92×4 | 0.92×4 | |
Static pressure | Pa | 0,20,40,60,80(Selectable) | |||
Air flow rate | m3/h | 30700 | 31600 | 31600 | |
Drive type | Direct | ||||
Refrigerant | Type | R410A | |||
Factory charge | kg | 20 | 20 | 20 | |
Pipe connections4 | Liquid pipe | mm | Φ19.1 | Φ19.1 | Φ19.1 |
Low pressure gas | mm | Φ34.9 | Φ34.9 | Φ41.3 | |
High pressure gas | mm | Φ28.6 | Φ28.6 | Φ34.9 | |
Sound pressure level5 | dB(A) | 68 | 68 | 68 | |
Sound power level5 | dB(A) | 91 | 91 | 91 | |
Net dimensions (W×H×D) | mm | (1340×1635×825)×2 | (1340×1635×825)×2 | (1340×1635×825)×2 | |
Packed dimensions (W×H×D) | mm | (1405×1805×910)×2 | (1405×1805×910)×2 | (1405×1805×910)×2 | |
Net weight | kg | 300×2 | 300×2 | 300×2 | |
Gross weight | kg | 325×2 | 325×2 | 325×2 | |
Ambient temp. operation range | Cooling6 | oC(DB) | -15 ~ 52 | ||
Heating | oC(WB) | -25 ~ 19 | |||
Domestic hot water | oC(DB) | -20 ~ 43 | |||
Notes: | |||||
1. Indoor air temperature 27°C DB, 19°C WB; outdoor air temperature 35°C DB; equivalent refrigerant piping length 7.5m with zero level difference. | |||||
2. Indoor air temperature 20°C DB; outdoor air temperature 7°C DB, 6°C WB; equivalent refrigerant piping length 7.5m with zero level difference. | |||||
3. Refer to table 1-5.1: Indoor and outdoor unit combination ratio limitations in Part 1. | |||||
4. Diameters given are those for the pipe connecting the outdoor unit combination to the first indoor branch joint for systems with total equivalent liquid piping lengths of less than 90m. For systems with total equivalent liquid piping lengths of 90m or longer, please refer to Part 3 “System Design and Installation” for connection piping diameters. | |||||
5. Sound pressure level is measured at a position 1m in front of the unit and 1.3m above the floor in a semi-anechoic chamber. | |||||
6. -15°C to -5°C low temperature cooling operation is just available for MS01. |
HP | 40 | 42 | 44 | ||
Model name | MV6-R1120WV2GN1 | MV6-R1185WV2GN1 | MV6-R1235WV2GN1 | ||
Combination type | 20HP+20HP | 12HP+14HP+16HP | 12HP+16HP+16HP | ||
Power supply | V/N/H | 380-415/3/50(60) | |||
Cooling1 | Capacity | kW | 112 | 118.5 | 123.5 |
Power input | kW | 34.78 | 30.46 | 32.64 | |
EER | 3.22 | 3.89 | 3.78 | ||
Heating2(Rated) | Capacity | kW | 112 | 118.5 | 123.5 |
Power input | kW | 29.53 | 24.62 | 26.13 | |
COP | 3.79 | 4.81 | 4.73 | ||
Heating2(Max) | Capacity | kW | 126 | 132.5 | 137.5 |
Power input | kW | 36.65 | 31.53 | 34.01 | |
COP | 3.44 | 4.20 | 4.04 | ||
Connected indoor unit |
Total capacity | 50-200% of outdoor unit capacity3 | |||
Maximum quantity | 64 | 64 | 64 | ||
Compressor | Type | DC inverter | |||
Quantity | 2 | 3 | 3 | ||
Oil type | FV68H | ||||
Start-up method | Soft start | ||||
Fan | Type | Propeller | |||
Motor type | DC | ||||
Quantity | 4 | 5 | 5 | ||
Motor output | kW | 0.92×4 | 0.92×5 | 0.92×5 | |
Static pressure | Pa | 0,20,40,60,80(Selectable) | |||
Air flow rate | m3/h | 31600 | 38900 | 39800 | |
Drive type | Direct | ||||
Refrigerant | Type | R410A | |||
Factory charge | kg | 20 | 28 | 28 | |
Pipe connections4 | Liquid pipe | mm | Φ19.1 | Φ19.1 | Φ19.1 |
Low pressure gas | mm | Φ41.3 | Φ41.3 | Φ41.3 | |
High pressure gas | mm | Φ34.9 | Φ34.9 | Φ34.9 | |
Sound pressure level5 | dB(A) | 68 | 67 | 68 | |
Sound power level5 | dB(A) | 91 | 89 | 91 | |
Net dimensions (W×H×D) | mm | (1340×1635×825)×2 | 990×1635×790+ (1340×1635×825)×2 | 990×1635×790+ (1340×1635×825)×2 | |
Packed dimensions (W×H×D) | mm | (1405×1805×910)×2 | 1090×1805×860+ (1405×1805×910)×2 | 1090×1805×860+ (1405×1805×910)×2 | |
Net weight | kg | 300×2 | 232+300×2 | 232+300×2 | |
Gross weight | kg | 325×2 | 248+325×2 | 248+325×2 | |
Ambient temp. operation range | Cooling6 | oC(DB) | -15 ~ 52 | ||
Heating | oC(WB | -25 ~ 19 | |||
Domestic hot water | oC(DB) | -20 ~ 43 | |||
Notes: | |||||
1. Indoor air temperature 27°C DB, 19°C WB; outdoor air temperature 35°C DB; equivalent refrigerant piping length 7.5m with zero level difference. | |||||
2. Indoor air temperature 20°C DB; outdoor air temperature 7°C DB, 6°C WB; equivalent refrigerant piping length 7.5m with zero level difference. | |||||
3. Refer to table 1-5.1: Indoor and outdoor unit combination ratio limitations in Part 1. | |||||
4. Diameters given are those for the pipe connecting the outdoor unit combination to the first indoor branch joint for systems with total equivalent liquid piping lengths of less than 90m. For systems with total equivalent liquid piping lengths of 90m or longer, please refer to Part 3 “System Design and Installation” for connection piping diameters. | |||||
5. Sound pressure level is measured at a position 1m in front of the unit and 1.3m above the floor in a semi-anechoic chamber. | |||||
6. -15°C to -5°C low temperature cooling operation is just available for MS01. |
HP | 46 | 48 | 50 | ||
Model name | MV6-R1300WV2GN1 | MV6-R1350WV2GN1 | MV6-R1400WV2GN1 | ||
Combination type | 14HP+16HP+16HP | 16HP+16HP+16HP | 16HP+16HP+18HP | ||
Power supply | V/N/Hz | 380-415/3/50(60) | |||
Cooling1 | Capacity | kW | 130 | 135 | 140 |
Power input | kW | 33.83 | 36.00 | 37.81 | |
EER | 3.84 | 3.75 | 3.70 | ||
Heating2(Rated) | Capacity | kW | 130 | 135 | 140 |
Power input | kW | 27.83 | 29.35 | 31.47 | |
COP | 4.67 | 4.60 | 4.45 | ||
Heating2(Max) | Capacity | kW | 145 | 150 | 156 |
Power input | kW | 34.31 | 36.79 | 39.29 | |
COP | 4.23 | 4.08 | 3.97 | ||
Connected indoor unit |
Total capacity | 50-200% of outdoor unit capacity3 | |||
Maximum quantity | 64 | 64 | 64 | ||
Compressor | Type | DC inverter | |||
Quantity | 3 | ||||
Oil type | FV68H | ||||
Start-up method | Soft start | ||||
Fan | Type | Propeller | |||
Motor type | DC | ||||
Quantity | 6 | 6 | 6 | ||
Motor output | kW | 0.92×6 | 0.92×6 | 0.92×6 | |
Static pressure | Pa | 0,20,40,60,80(Selectable) | |||
Air flow rate | m3/h | 43800 | 44700 | 45600 | |
Drive type | Direct | ||||
Refrigerant | Type | R410A | |||
Factory charge | kg | 30 | 30 | 30 | |
Pipe connections4 | Liquid pipe | mm | Φ19.1 | Φ19.1 | Φ19.1 |
Low pressure gas pipe | mm | Φ41.3 | Φ41.3 | Φ41.3 | |
High pressure gas | mm | Φ34.9 | Φ34.9 | Φ34.9 | |
Sound pressure level5 | dB(A) | 68 | 69 | 69 | |
Sound power level5 | dB(A) | 91 | 93 | 93 | |
Net dimensions (W×H×D) | mm | (1340×1635×825)×3 | (1340×1635×825)×3 | (1340×1635×825)×3 | |
Packed dimensions (W×H×D) | mm | (1405×1805×910)×3 | (1405×1805×910)×3 | (1405×1805×910)×3 | |
Net weight | kg | 300×3 | 300×3 | 300×3 | |
Gross weight | kg | 325×3 | 325×3 | 325×3 | |
Ambient temp. operation range |
Cooling6 | oC(DB) | -15 ~ 52 | ||
Heating | oC(WB) | -25 ~ 19 | |||
Domestic hot water | oC(DB) | -20 ~ 43 | |||
Notes: | |||||
1. Indoor air temperature 27°C DB, 19°C WB; outdoor air temperature 35°C DB; equivalent refrigerant piping length 7.5m with zero level difference. | |||||
2. Indoor air temperature 20°C DB; outdoor air temperature 7°C DB, 6°C WB; equivalent refrigerant piping length 7.5m with zero level difference. | |||||
3. Refer to table 1-5.1: Indoor and outdoor unit combination ratio limitations in Part 1. | |||||
4. Diameters given are those for the pipe connecting the outdoor unit combination to the first indoor branch joint for systems with total equivalent liquid piping lengths of less than 90m. For systems with total equivalent liquid piping lengths of 90m or longer, please refer to Part 3 “System Design and Installation” for connection piping diameters. | |||||
5. Sound pressure level is measured at a position 1m in front of the unit and 1.3m above the floor in a semi-anechoic chamber. | |||||
6. -15°C to -5°C low temperature cooling operation is just available for MS01. |
HP | 52 | 54 | 56 | ||
Model name | MV6-R1450WV2GN1 | MV6-R1500WV2GN1 | MV6-R1560WV2GN1 | ||
Combination type | 16HP+18HP+18HP | 18HP+18HP+18HP | 18HP+18HP+20HP | ||
Power supply | V/N/Hz | 380-415/3/50(60) | |||
Cooling1 | Capacity | kW | 145 | 150 | 156 |
Power input | kW | 39.62 | 41.44 | 45.01 | |
EER | 3.66 | 3.62 | 3.47 | ||
Heating2(Rated) | Capacity | kW | 145 | 150 | 156 |
Power input | kW | 33.59 | 35.71 | 38.58 | |
COP | 4.32 | 4.20 | 4.04 | ||
Heating2(Max) | Capacity | kW | 162 | 168 | 175 |
Power input | kW | 41.80 | 44.30 | 47.86 | |
COP | 3.97 | 3.88 | 3.79 | ||
Connected indoor unit |
Total capacity | 50-200% of outdoor unit capacity3 | |||
Maximum quantity | 64 | 64 | 64 | ||
Compressor | Type | DC inverter | |||
Quantity | 3 | ||||
Oil type | FV68H | ||||
Start-up method | Soft start | ||||
Fan | Type | Propeller | |||
Motor type | DC | ||||
Quantity | 6 | 6 | 6 | ||
Motor output | kW | 0.92×6 | 0.92×6 | 0.92×6 | |
Static pressure | Pa | 0,20,40,60,80(Selectable) | |||
Air flow rate | m3/h | 46500 | 47400 | 47400 | |
Drive type | Direct | ||||
Refrigerant | Type | R410A | |||
Factory charge | kg | 30 | 30 | 30 | |
Pipe connections4 | Liquid pipe | mm | Φ19.1 | Φ19.1 | Φ19.1 |
Low pressure gas | mm | Φ41.3 | Φ41.3 | Φ41.3 | |
High pressure gas | mm | Φ34.9 | Φ34.9 | Φ34.9 | |
Sound pressure level5 | dB(A) | 69 | 70 | 70 | |
Sound power level5 | dB(A) | 93 | 93 | 93 | |
Net dimensions (W×H×D) | mm | (1340×1635×825)×3 | (1340×1635×825)×3 | (1340×1635×825)×3 | |
Packed dimensions (W×H×D) | mm | (1405×1805×910)×3 | (1405×1805×910)×3 | (1405×1805×910)×3 | |
Net weight | kg | 300×3 | 300×3 | 300×3 | |
Gross weight | kg | 325×3 | 325×3 | 325×3 | |
Ambient temp. operation range | Cooling6 | oC(DB) | -15 ~ 52 | ||
Heating | oC(WB) | -25 ~ 19 | |||
Domestic hot | oC(DB) | -20 ~ 43 | |||
Notes: | |||||
1. Indoor air temperature 27°C DB, 19°C WB; outdoor air temperature 35°C DB; equivalent refrigerant piping length 7.5m with zero level difference. | |||||
2. Indoor air temperature 20°C DB; outdoor air temperature 7°C DB, 6°C WB; equivalent refrigerant piping length 7.5m with zero level difference. | |||||
3. Refer to table 1-5.1: Indoor and outdoor unit combination ratio limitations in Part 1. | |||||
4. Diameters given are those for the pipe connecting the outdoor unit combination to the first indoor branch joint for systems with total equivalent liquid piping lengths of less than 90m. For systems with total equivalent liquid piping lengths of 90m or longer, please refer to Part 3 “System Design and Installation” for connection piping diameters. | |||||
5. Sound pressure level is measured at a position 1m in front of the unit and 1.3m above the floor in a semi-anechoic chamber. | |||||
6. -15°C to -5°C low temperature cooling operation is just available for MS01. |
HP | 58 | 60 | ||
Model name | MV6-R1620WV2GN1 | MV6-R1680WV2GN1 | ||
Combination type | 18HP+20HP+20HP | 20HP+20HP+20HP | ||
Power supply | V/N/Hz | 380-415/3/50(60) | ||
Cooling1 | Capacity | kW | 162 | 168 |
Power input | kW | 48.59 | 52.17 | |
EER | 3.33 | 3.22 | ||
Heating2(Rated) | Capacity | kW | 162 | 168 |
Power input | kW | 41.44 | 44.30 | |
COP | 3.91 | 3.79 | ||
Heating2(Max) | Capacity | kW | 182 | 189 |
Power input | kW | 51.42 | 54.98 | |
COP | 3.54 | 3.44 | ||
Connected indoor unit | Total capacity | 50-200% of outdoor unit capacity | ||
Maximum quantity | 64 | 64 | ||
Compressor | Type | DC inverter | ||
Quantity | 3 | |||
Oil type | FV68H | |||
Start-up method | Soft start | |||
Fan | Type | Propeller | ||
Motor type | DC | |||
Quantity | 6 | 6 | ||
Motor output | kW | 0.92×6 | 0.92×6 | |
Static pressure | Pa | 0,20,40,60,80(Selectable) | ||
Air flow rate | m3/h | 47400 | 47400 | |
Drive type | Direct | |||
Refrigerant | Type | R410A | ||
Factory charge | kg | 30 | 30 | |
Pipe connections3 | Liquid pipe | mm | Φ19.1 | Φ19.1 |
Low pressure gas pipe | mm | Φ41.3 | Φ41.3 | |
High pressure gas pipe | mm | Φ34.9 | Φ34.9 | |
Sound pressure level4 | dB(A) | 70 | 70 | |
Sound power level4 | dB(A) | 93 | 93 | |
Net dimensions (W×H×D) | mm | (1340×1635×825)×3 | (1340×1635×825)×3 | |
Packed dimensions (W×H×D) | mm | (1405×1805×910)×3 | (1405×1805×910)×3 | |
Net weight | kg | 300×3 | 300×3 | |
Gross weight | kg | 325×3 | 325×3 | |
Ambient temp. operation range | Cooling | oC(DB) | -15 ~ 52 | |
Heating | oC(WB) | -25 ~ 19 | ||
Domestic hot water | oC(DB) | -20 ~ 43 | ||
Notes: | ||||
1. Indoor air temperature 27°C DB, 19°C WB; outdoor air temperature 35°C DB; equivalent refrigerant piping length 7.5m with zero level difference. | ||||
2. Indoor air temperature 20°C DB; outdoor air temperature 7°C DB, 6°C WB; equivalent refrigerant piping length 7.5m with zero level difference. | ||||
3. Refer to table 1-5.1: Indoor and outdoor unit combination ratio limitations in Part 1. | ||||
4. Diameters given are those for the pipe connecting the outdoor unit combination to the first indoor branch joint for systems with total equivalent liquid piping lengths of less than 90m. For systems with total equivalent liquid piping lengths of 90m or longer, please refer to Part 3 “System Design and Installation” for connection piping diameters. | ||||
5. Sound pressure level is measured at a position 1m in front of the unit and 1.3m above the floor in a semi-anechoic chamber. | ||||
6. -15°C to -5°C low temperature cooling operation is just available for MS01. |
Model name | MS01/N1-D1 | MS04/N1-D | MS06/N1-D | ||
Power supply | V/ph/Hz | 220-240/1/50(60) | |||
Max. number of indoor unit groups | 1 | 4 | 6 | ||
Max. number of units per group | 8 | 5 | 5 | ||
Max. number of downstream indoor units | 8 | 20 | 30 | ||
Max. capacity of each group of indoor units | kW | 32 | 16 | 16 | |
Total capacity of downstream indoor units | kW | 32 | 49 | 63 | |
Pipe connections to ODU |
Liquid pipe | mm | ∅9.53/∅12.7 | ∅9.53/∅12.7/∅15.9/∅19.05 | ∅9.53/∅12.7/∅15.9/∅19.05 |
Low pressure gas pipe |
mm | ∅15.9/∅19.1/∅22.2 | ∅19.1/∅22.2/∅28.6 | ∅19.1/∅22.2/∅28.6 | |
High pressure gas pipe | mm | ∅12.7/∅15.9/∅19.1 | ∅15.9/∅19.1/∅22.2/∅28.6 | ∅15.9/∅19.1/∅22.2/∅28.6 | |
Pipe connections to IDU |
Liquid pipe | mm | ∅6.35/∅9.53 | ∅6.35/∅9.53 | ∅6.35/∅9.53 |
Gas pipe | mm | ∅12.7/∅15.9 | ∅12.7/∅15.9 | ∅12.7/∅15.9 | |
Sound pressure level2 | dB(A) | 40 | 44 | 45 | |
Sound power level2 | dB(A) | 60 | 63 | 65 | |
Net dimensions (W×H×D) | mm | 440×195×296 | 668×250×574 | 668×250×574 | |
Packed dimensions (W×H×D) | mm | 740×275×405 | 1020×390×850 | 1020×390×850 | |
Net weight | kg | 10.5 | 33 | 36 | |
Gross weight | kg | 14 | 58 | 61 | |
Notes: | |||||
1. MS01 is for low temperature cooling operation and leakage detection. | |||||
2. The sound level is measured at a position 1m below the MS box in a semi-anechoic chamber whilst the MS box is switching mode. MS box should not be installed in locations with low-noise requirements. |
Model name | MS08/N1-D | MS10/N1-D | MS12/N1-D | ||
Power supply | V/ph/Hz | 220-240/1/50(60) | |||
Max. number of indoor unit groups | 8 | 10 | 12 | ||
Max. number of units per group | 5 | 5 | 5 | ||
Max. number of downstream indoor units | 40 | 47 | 47 | ||
Max. capacity of each group of indoor units | kW | 16 | 16 | 16 | |
Total capacity of downstream indoor units | kW | 85 | 85 | 85 | |
Pipe connections to ODU |
Liquid pipe | mm | ∅12.7/∅15.9/∅19.1/∅22.2 | ∅12.7/∅15.9/∅19.1/∅22.2 | ∅12.7/∅15.9/∅19.1/∅22.2 |
Low pressure gas pipe |
mm | ∅22.2/∅28.6/∅34.9 | ∅22.2/∅28.6/∅34.9 | ∅22.2/∅28.6/∅34.9 | |
High pressure gas pipe | mm | ∅19.1/∅22.2/∅28.6 | ∅19.1/∅22.2/∅28.6 | ∅19.1/∅22.2/∅28.6 | |
Pipe connections to IDU |
Liquid pipe | mm | ∅6.35/∅9.53 | ∅6.35/∅9.53 | ∅6.35/∅9.53 |
Gas pipe | mm | ∅12.7/∅15.9 | ∅12.7/∅15.9 | ∅12.7/∅15.9 | |
Sound pressure level1 | dB(A) | 47 | 47 | 47 | |
Sound power level1 | dB(A) | 65 | 65 | 65 | |
Net dimensions (W×H×D) | mm | 974×250×574 | 974×250×574 | 974×250×574 | |
Packed dimensions (W×H×D) | mm | 1320×390×850 | 1320×390×850 | 1320×390×850 | |
Net weight | kg | 48 | 51 | 54 | |
Gross weight | kg | 79 | 82 | 85 | |
Notes: | |||||
1. The sound level is measured at a position 1m below the MS box in a semi-anechoic chamber whilst the MS box is switching mode. MS box should not be installed in locations with low-noise requirements. |