Operating ambient temperatures
Suggested retail price
Technology
Wired remote control for indoor unit
The internal block is completed / can be completed (option) with the wire control panel.
General functional features:
- Connection to indoor units using stranded wire.
- The job modes.3. Set the fan speed.
- Display information about operating modes on the LCD.
- Setting the time of automatic on / off using a timer.
Sine-Wave Inverter
Technology 180° -gradusnogo wave inverter conversion - control voltage without the "pulse" effects (jagged sinusoid).
Compared with the current standard of 120° rectangular wave has the following advantages:
- Ability to work with a wider range of supply voltage and frequency.
- Most of the energy efficiency and energy conservation.
- More soft start, lower noise and vibration.
- more control.
Aluminium heat exchanger with hydrophilic coating
Improved wettability of the heat exchanger aluminum plates which have a special coating with a hydrophilic layer, ensuring rapid removal of condensate from the indoor unit that does not allow to quickly form of mold and bacteria, providing a more efficient operation of the air conditioner.
Compresor DC inverter
Compressor with inverter DC can increase the efficiency of the air conditioner, thus reducing power consumption saves your costs. This system is much more economical and safer than air conditioners with a constant output of the compressor.
Easy Maintenance
More than 60% parts and assemblies (such as fan wheel, plastic cases, metal parts and etc.) are universal for 3 different bodies, which makes the production and maintenance much easier.
Multi-Bend Heat Exchanger
Increased heat. This unit uses the heat exchangers with tubes of a special design, the inner surface of which has trapezoidal notches "Innergrove cooper", which provides maximum heat transfer surface area increased. Due to this heat increases by 28%, reduced power consumption, and hence increases the efficiency of the system.
Full-DC (3D DC-inverter)
All engines compressors and fans in the system are made by DC-inverter technology.
Description
Maximum capacity of indoor units 64 to 130% of outdoor units "may be combined into a single cooling system. It is especially suitable for office buildings, hotels, apartments, waiting rooms, hospitals and so forth.
To connect the indoor unit to the grid and connect them to the outdoor unit and the central console, use a 3-wire shielded cable (0.75mm2), which is connected to the terminals with the correct polarity.
External power can allocate addresses for each indoor unit automatically. However, wired (wireless) controller (RC) can be invited and manually change any address of the indoor unit.
- The total length of the pipes can be 1000 m
- Maximum actual length 175 m routes are
- The maximum equivalent pipe length of 200 m
- Equivalent length of pipe from the first installed indoors rifneta to the most distant indoor unit - 40/90 (When the equivalent length of pipe from the first installed inside the premises of the splitter to the farthest indoor unit more than 40 m, it must comply with specific conditions in accordance with the technical manual for the equipment)
Specifications
Options |
MV5-X252W/V2GN1 |
MV5-X280W/V2GN1 |
MV5-X335W/V2GN1 |
MV5-X400W/V2GN1 |
MV5-X450W/V2GN1 |
MV5-X500W/V2GN1 |
MV5-X560W/V2GN1 |
MV5-X615W/V2GN1 |
|
Power supply, V/Hz/Ph |
380/50/3 |
380/50/3 |
380/50/3 |
380/50/3 |
380/50/3 |
380/50/3 |
380/50/3 |
380/50/3 |
|
Power |
Cooling,kW |
25.20 |
28.00 |
33.50 |
40.0 |
45.0 |
50.0 |
56.0 |
61.5 |
Heating,kW |
27.0 |
31.5 |
37.5 |
45.0 |
50.0 |
56.0 |
63.0 |
69.0 |
|
Power consumption |
Cooling,kW |
5.79 |
7.02 |
8.71 |
10.81 |
12.83 |
14.47 |
16.67 |
18.77 |
Heating,kW |
5.79 |
7.19 |
8.82 |
10.98 |
12.47 |
14.15 |
15.98 |
17.86 |
|
Refrigerant type |
R410 |
R410 |
R410 |
R410 |
R410 |
R410 |
R410 |
R410 |
|
Product dimensions (WxHxD), mm |
990x1635x790 |
990x1635x790 |
990x1635x790 |
1340x1635x790 |
1340x1635x790 |
1340x1635x790 |
1340x1635x790 |
1340x1635x790 |
|
Weight, net/gross, kg |
219/234 |
219/234 |
237/252 |
297/315 |
297/315 |
305/323 |
340/358 |
340/358 |
|
Airflow, m³/h |
10800 |
10800 |
10800 |
14000 |
14000 |
15500 |
15500 |
15500 |
|
The noise level, dB |
43-58 |
43-59 |
43-60 |
43-62 |
43-62 |
43-63 |
43-63 |
43-63 |
|
Max. vertical drop, ODU above IDU / ODU below IDU, m |
70/110 |
70/110 |
70/110 |
70/110 |
70/110 |
70/110 |
70/110 |
70/110 |
|
The actual length of the piping of the refrigerant circuit, m |
1000 |
1000 |
1000 |
1000 |
1000 |
1000 |
1000 |
1000 |
|
Equivalent piping length of the refrigerant circuit, m |
200 |
200 |
200 |
200 |
200 |
200 |
200 |
200 |
|
The maximum number of indoor units, pcs. |
13 |
16 |
19 |
23 |
26 |
29 |
33 |
36 |
|
Allowable load range in the indices of indoor units,% |
50-130 |
50-130 |
50-130 |
50-130 |
50-130 |
50-130 |
50-130 |
50-130 |