Midea "Outdoor units DC Inverter split type, series V6 Slim individual"

Operating ambient temperatures

Cooling mode
- 5
... + 48 °C
Heating mode
- 20
... + 24 °C

Suggested retail price

155,800- ... 227,550-hrv.

    Sine-Wave Inverter

    Technology 180° -gradusnogo wave inverter conversion - control voltage without the "pulse" effects (jagged sinusoid).

    Compared with the current standard of 120° rectangular wave has the following advantages:

    1. Ability to work with a wider range of supply voltage and frequency.
    2. Most of the energy efficiency and energy conservation.
    3. More soft start, lower noise and vibration.
    4. more control.

    Compresor DC inverter

    Compressor with inverter DC can increase the efficiency of the air conditioner, thus reducing power consumption saves your costs. This system is much more economical and safer than air conditioners with a constant output of the compressor.

    Multi-Bend Heat Exchanger

    Increased heat. This unit uses the heat exchangers with tubes of a special design, the inner surface of which has trapezoidal notches "Innergrove cooper", which provides maximum heat transfer surface area increased. Due to this heat increases by 28%, reduced power consumption, and hence increases the efficiency of the system.

    • Budget outdoor units in VRF class;

    • Optimal solution for small buildings;

    • Long track length;

    • Highly efficient compressor DC-Inverter;

    • Wide range of 20–33.5 kW;

    • G-shaped heat exchanger with hydrophilic coating;

    • Updated intelligent control system;

    • Fans based on DC motors with improved blade aerodynamics;

    • Load range (according to the sum of indices of indoor units) 15–130%;

    • Autorestart with restoration of operating parameters, with an oil return cycle;

    • Strong protective grille for fans;

    • Precise temperature control - by changing the compressor frequency and the EXV multi-position valve.

    HP 7 8 9
    Model name MVi-200WV2RN1(A) MVi-224WV2RN1(A) MVi-260WV2RN1(A)
    Power supply V/Ph/Hz 380-415/3/50
    Cooling1 Capacity kW 20 22.4 26.0
    Power input kW 5.28 6.77 10.04
    EER 3.79 3.31 2.59
    Heating2
    (Rated)
    Capacity kW 20 22.4 26.0
    Power input kW 4.43 5.42 6.86
    COP 4.51 4.13 3.79
    Heating3 (Max.) Capacity kW 22.5 25.0 28.5
    Power input kW 5.95 6.67 7.70
    COP 3.78 3.75 3.70
    Connected
    indoor unit
    Total capacity 50-130% of outdoor unit capacity
    Maximum quantity 11 13 15
    Compressor Type DC inverter rotary
    Quantity 1
    Oil type RB75EA
    Start-up method Soft start
    Fan Type Propeller
    Motor type DC
    Quantity 2
    Motor output kW 0.17×2 0.17×2 0.17×2
    Air flow rate m3/h 9000 9000 10000
    Drive type Direct
    Refrigerant Type R410A
    Factory charge kg 6.5 6.5 6.5
    Pipe
    connections4
    Liquid pipe mm Ф9.53 Ф9.53 Ф9.53
    Gas pipe mm Ф19.1 Ф19.1 Ф22.2
    Sound pressure level5 dB(A) 58 58 59
    Sound power level5 dB(A) 78 78 78
    Net dimensions (W×H×D) mm 1120×1558×528
    Packed dimensions (W×H×D) mm 1270×1720×565
    Net weight kg 143 143 144
    Gross weight kg 159 159 160
    Ambient Temp. operation
    range
    Cooling oC -5~48
    Heating oC -20~24
    Notes:
    1. Indoor temperature 27°C DB, 19°C WB; outdoor temperature 35°C DB; equivalent refrigerant piping length 7.5m with zero level difference.
    2. Indoor temperature 20°C DB; outdoor temperature 7°C DB, 6°C WB; equivalent refrigerant piping length 7.5m with zero level difference.
    3. Indoor temperature 20°C DB; outdoor temperature 7°C DB, 6°C WB; equivalent refrigerant piping length 7.5m with zero level difference.
    4. Diameters given are those of the unit's stop valves.
    5. Sound pressure level is measured at a position 1m in front of the unit and 1m above the floor in a semi-anechoic chamber.
    HP 10 12  
    Model name MVi-280WV2RN1(A) MVi-335WV2RN1(A)  
    Power supply V/Ph/Hz 380-415/3/50  
    Cooling1 Capacity kW 28.5 33.5  
    Power input kW 12.23 15.30  
    EER 2.33 2.19  
    Heating2 (Rated) Capacity kW 28.5 33.5  
    Power input kW 7.68 10.15  
    COP 3.71 3.30  
    Heating3 (Max.) Capacity kW 31.5 37.5  
    Power input kW 7.87 11.72  
    COP 4.00 3.20  
    Connected    indoor
    unit
    Total capacity 50-130% of outdoor unit capacity  
    Maximum quantity 16 20  
    Compressor Type DC inverter rotary  
    Quantity 1 1  
    Oil type RB75EA FV50S  
    Start-up method Soft start  
    Fan Type Propeller    
    Motor type DC    
    Quantity 2    
    Motor output kW 0.17×2 0.17×2  
    Air flow rate m3/h 11000 11300  
    Drive type Direct    
    Refrigerant Type R410A    
    Factory charge kg 6.5 8  
    Pipe connections4 Liquid pipe mm Φ9.53 Φ12.7  
    Gas pipe mm Φ22.2 Φ25.4  
    Sound pressure level5 dB(A) 60 61  
    Sound power level5 dB(A) 78 81  
    Net dimensions (W×H×D) mm 1120×1558×528    
    Packed dimensions (W×H×D) mm 1270×1720×565    
    Net weight kg 144 157  
    Gross weight kg 160 173  
    Ambient Temp. operation range Cooling oC -5~48    
    Heating oC -20~24    
    Notes:
    1. Indoor temperature 27°C DB, 19°C WB; outdoor temperature 35°C DB; equivalent refrigerant piping length 7.5m with zero level difference.
    2. Indoor temperature 20°C DB; outdoor temperature 7°C DB, 6°C WB; equivalent refrigerant piping length 7.5m with zero level difference.
    3. Indoor temperature 20°C DB; outdoor temperature 7°C DB, 6°C WB; equivalent refrigerant piping length 7.5m with zero level difference.
    4. Diameters given are those of the unit's stop valves.
    5. Sound pressure level is measured at a position 1m in front of the unit and 1m above the floor in a semi-anechoic chamber.