Operating ambient temperatures
Suggested retail price
Technology
Aluminium heat exchanger with hydrophilic coating
Improved wettability of the heat exchanger aluminum plates which have a special coating with a hydrophilic layer, ensuring rapid removal of condensate from the indoor unit that does not allow to quickly form of mold and bacteria, providing a more efficient operation of the air conditioner.
Compresor DC inverter
Compressor with inverter DC can increase the efficiency of the air conditioner, thus reducing power consumption saves your costs. This system is much more economical and safer than air conditioners with a constant output of the compressor.
Multi-Bend Heat Exchanger
Increased heat. This unit uses the heat exchangers with tubes of a special design, the inner surface of which has trapezoidal notches "Innergrove cooper", which provides maximum heat transfer surface area increased. Due to this heat increases by 28%, reduced power consumption, and hence increases the efficiency of the system.
Full-DC (3D DC-inverter)
All engines compressors and fans in the system are made by DC-inverter technology.
Description
The range of equipment to create small systems - small-scale shop or office. Load Range (the sum of the indices of indoor units) available from 45 to 120%. For Mini VRF MDV systems manufactured by technology Full DC-Inverter, possible to use a central console CCM02 c followed by the withdrawal of at BMS, or a computer program to analyze energy consumption.
In 2021 will be deliveries of Mini VRF MDV systems manufactured using the "Full DCInverter" technology, the model range of which is represented by outdoor units with a power of 8-16 kW, with power 220V and 380 V.
In this series of blocks used modern Innovative technical solutions, namely:
- Twin-rotor DC-Inverter compressor with high efficiency and low noise and vibration;
- Fan motors DC-Inverter (development of Panasonic), the efficiency of which is 30% higher than that of "ordinary" (AC motors);
- A heat exchanger coated with protective «Blue fin», which have increased corrosion resistance;
- Branch-providers are delivered only 4-port and in the 16 kW is possible to use not more than 2 providers, arranged in parallel
- Piping to the ports of the outdoor unit is allowed on either side (side, front, bottom, rear);
- 2 options allowed the organization line to the indoor unit - branch or rush through a special switching units Refrigerant (Branch-providers FTQ4-01); In this architecture, the distance from the ports of the outdoor unit to the ports of Branch-provider - up to 25 meters. The distance from the provider to the indoor units can be in the range of 1-20 m. In the application of the scheme to the ISP restrictions on height difference tougher: 8 -20 meters, depending on the horizontal distance.
- Blocks eoy series have a high coefficient of energy efficiency, especially in partial load system.
Specifications
Feature / model | MDV-V 80W/DN1 |
MDV-V 100W/DN1 |
MDV-V 105W/BDRN1 |
MDV-V 120W/DN1 |
MDV-V 140W/N1 |
MDV-V 140W/DRN1 |
MDV-V 140W/BDRN1 |
MDV-V 160W/DRN1 |
MDV-V 160W/BDRN1 |
MDV-V 180W/DRN1 |
---|---|---|---|---|---|---|---|---|---|---|
Сompressors Type(technology) | Full DC-Inverter | Full DC-Inverter | Full DC-Inverter | Full DC-Inverter | Full DC-Inverter | Full DC-Inverter | Full DC-Inverter | Full DC-Inverter | Full DC-Inverter | Full DC-Inverter |
Power, V/Hz/Ph | 220/50/1 | 220/50/1 | 380/50/3 | 220/50/1 | 220/50/1 | 380/50/3 | 380/50/3 | 380/50/3 | 380/50/3 | 380/50/3 |
Cooling Power, kW | 8,0 | 10,0 | 10,5 | 12,0 | 14,0 | 14,0 | 14,0 | 15,5 | 16,0 | 17,5 |
Heating Power, kW |
9,0 |
11,5 | 11,5 | 13,2 | 15,0 | 15.4 | 15,5 | 17,0 | 17,1 | 19,0 |
Power Consumption, Cooling, kW | 2,05 | 2,68 | 3,38 | 3,25 | 4,36 | 3.95 | 3,98 | 4,52 | 4,58 | 5,3 |
Power Consumption, Heating, kW |
2,24 | 2,68 | 3,61 | 3,25 | 4,13 | 4.16 | 3,98 | 4,77 | 4,58 | 5,0 |
Dimensions without packing, (WxHxD), mm | 975x862x355 | 966x1075х396 | 966х990х354 | 900x1327x320 | 940х1245х360 | 900x1327x320 | 900x1327x320 | 900x1327x320 | 900x1327x320 | 900x1327x320 |
Weight, Net/Gross, kg | 108/116 | 108/116 | 104/111 | 112/125 | 108/116 | 95/106 | 115/121 | 102/113 | 124/133 | 107/118 |
Noise Level, dB | 57,5 | 62,1 | 56 | 56,2 | 57 | 57 | 57 | 57 | 58 | 59 |
Air Flow, m3/hour | 6500 | 5400 | 5400 | 6000 | 6500/4800 | 6000 | 6500 | 6000 | 6500 | 6800 |
Maximum height difference, m | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 |
The actual length of the pipelines of the refrigerant circuit, m |
45 | 45 | 45 | 45 | 45 | 45 | 45 | 45 | 60 | 45 |
Equivalent piping length of the refrigerant circuit, m |
50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 70 | 50 |
The maximum length interblock pipes, m |
100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 |
The maximum number of indoor units, pcs. |
4 | 5 | 5 | 6 | 8 | 6 | 6 | 7 | 7 | 9 |
Permissible load range for the index within. blocks, min/max. % |
45/120 | 45/120 | 50/130 | 45/120 | 50/130 | 50/130 | 45/120 | 50/130 | 45/120 | 50/130 |