Midea "Outdoor units systems Mini VRF"

Operating ambient temperatures

Cooling mode
- 5
... + 48 °C
Heating mode
- 15
... + 27 °C

Suggested retail price

0-hrv.

    Compresor DC inverter

    Compressor with inverter DC can increase the efficiency of the air conditioner, thus reducing power consumption saves your costs. This system is much more economical and safer than air conditioners with a constant output of the compressor.

    Multi-Bend Heat Exchanger

    Increased heat. This unit uses the heat exchangers with tubes of a special design, the inner surface of which has trapezoidal notches "Innergrove cooper", which provides maximum heat transfer surface area increased. Due to this heat increases by 28%, reduced power consumption, and hence increases the efficiency of the system.

    The range of equipment to create small systems - small-scale shop or office. Load Range (the sum of the indices of indoor units) available from 45 to 120%. For Mini VRF MDV systems manufactured by technology Full DC-Inverter, possible to use a central console CCM02 c followed by the withdrawal of at BMS, or a computer program to analyze energy consumption.
    In 2021 will be deliveries of Mini VRF MDV systems manufactured using the "Full DCInverter" technology, the model range of which is represented by outdoor units with a power of 8-16 kW, with power 220V and 380 V.

    In this series of blocks used modern Innovative technical solutions, namely:

    •     Twin-rotor DC-Inverter compressor with high efficiency and low noise and vibration;
    •     Fan motors DC-Inverter (development of Panasonic), the efficiency of which is 30% higher than that of "ordinary" (AC motors);
    •     A heat exchanger coated with protective «Blue fin», which have increased corrosion resistance;
    •     Branch-providers are delivered only 4-port and in the 16 kW is possible to use not more than 2 providers, arranged in parallel
    •     Piping to the ports of the outdoor unit is allowed on either side (side, front, bottom, rear);
    •     2 options allowed the organization line to the indoor unit - branch or rush through a special switching units Refrigerant (Branch-providers FTQ4-01); In this architecture, the distance from the ports of the outdoor unit to the ports of Branch-provider - up to 25 meters. The distance from the provider to the indoor units can be in the range of 1-20 m. In the application of the scheme to the ISP restrictions on height difference tougher: 8 -20 meters, depending on the horizontal distance.
    •     Blocks eoy series have a high coefficient of energy efficiency, especially in partial load system.
     
    Feature / model MDV-V
    80W/DN1
    MDV-V
    100W/DN1
    MDV-V
    105W/BDRN1
    MDV-V
    120W/DN1
    MDV-V
    140W/N1
    MDV-V
    140W/DRN1
    MDV-V
    140W/BDRN1
    MDV-V
    160W/DRN1
    MDV-V
    160W/BDRN1
    MDV-V
    180W/DRN1
    Сompressors Type(technology) Full DC-Inverter Full DC-Inverter Full DC-Inverter Full DC-Inverter Full DC-Inverter Full DC-Inverter Full DC-Inverter Full DC-Inverter Full DC-Inverter Full DC-Inverter
    Power, V/Hz/Ph 220/50/1 220/50/1 380/50/3 220/50/1 220/50/1 380/50/3 380/50/3 380/50/3 380/50/3 380/50/3
    Cooling Power, kW 8,0 10,0 10,5 12,0 14,0 14,0 14,0 15,5 16,0 17,5
    Heating Power, kW

    9,0

    11,5 11,5 13,2 15,0 15.4 15,5 17,0 17,1 19,0
    Power Consumption, Cooling, kW 2,05 2,68 3,38 3,25 4,36 3.95 3,98 4,52 4,58 5,3

    Power Consumption, Heating, kW

    2,24 2,68 3,61 3,25 4,13 4.16 3,98 4,77 4,58 5,0
    Dimensions without packing, (WxHxD), mm 975x862x355 966x1075х396 966х990х354 900x1327x320 940х1245х360 900x1327x320 900x1327x320 900x1327x320 900x1327x320 900x1327x320
    Weight, Net/Gross, kg 108/116 108/116 104/111 112/125 108/116 95/106 115/121 102/113 124/133 107/118
    Noise Level, dB 57,5 62,1 56 56,2 57 57 57 57 58 59
    Air Flow, m3/hour 6500 5400 5400 6000 6500/4800 6000 6500 6000 6500 6800
    Maximum height difference, m 20 20 20 20 20 20 20 20 20 20
    The actual length of the pipelines
    of the refrigerant circuit, m
    45 45 45 45 45 45 45 45 60 45
    Equivalent piping length
    of the refrigerant circuit, m
    50 50 50 50 50 50 50 50 70 50
    The maximum length
    interblock pipes, m
    100 100 100 100 100 100 100 100 100 100
    The maximum number
    of indoor units, pcs.
    4 5 5 6 8 6 6 7 7 9
    Permissible load range
    for the index within. blocks, min/max. %
    45/120 45/120 50/130 45/120 50/130 50/130 45/120 50/130 45/120 50/130