Midea "Outdoor units DC-МУЛЬТІ PRO systems, series Atom"

Operating ambient temperatures

Cooling mode
- 5
... + 55 °C
Heating mode
- 15
... + 27 °C

Suggested retail price

54,530- ... 102,090-hrv.

    Sine-Wave Inverter

    Technology 180° -gradusnogo wave inverter conversion - control voltage without the "pulse" effects (jagged sinusoid).

    Compared with the current standard of 120° rectangular wave has the following advantages:

    1. Ability to work with a wider range of supply voltage and frequency.
    2. Most of the energy efficiency and energy conservation.
    3. More soft start, lower noise and vibration.
    4. more control.

    Compresor DC inverter

    Compressor with inverter DC can increase the efficiency of the air conditioner, thus reducing power consumption saves your costs. This system is much more economical and safer than air conditioners with a constant output of the compressor.

    Multi-Bend Heat Exchanger

    Increased heat. This unit uses the heat exchangers with tubes of a special design, the inner surface of which has trapezoidal notches "Innergrove cooper", which provides maximum heat transfer surface area increased. Due to this heat increases by 28%, reduced power consumption, and hence increases the efficiency of the system.

    Low Ambient Cooling

    Low-temperature (season) set - used for the operation of the air conditioner in cooling mode at low ambient temperatures (usually provided in the air conditioner as an optional feature). The kit includes: the controller of the outdoor unit fan motor, compressor crankcase heater and heater drain line.

    In some series of inverter split systems this option is implemented in hardware and software, thus if there is a need to use the air conditioner in the winter for cooling, you must install only drain the heater.

    • ATOM is ideal for commercial and residential applications, small offices, villas, apartments, shops, etc.
    • ATOM requires less maintenance and is easier to install than other mini VRFs - safe and fast installation that does not require soldering (no fire). All connections between the outdoor unit, splitter and indoor units are for rolling.
    • ATOM is compatible with a variety of indoor units and highly flexible control solutions for home and commercial applications.
    • ATOM uses more efficient DC Inverter technology, which means it consumes less electricity.
    • ATOM is the ultimate multi-zone mini VRF system that provides a comfortable indoor environment yet is quiet and unobtrusive during normal operation.
    Model MDV-V28WDHN1(AtB) MDV-V36WDHN1(AtB) MDV-V42WDHN1(AtB)
    Power supply V-Ph-Hz 220-240/1/ 50(60)
    Cooling1 Capacity kBtu/h 27 34 41
    kW 8 10 12
    Input kW 2.1 2.66 3.31
    EER kW/ KW 3.81 3.76 3.63
    Heating2 Capacity kBtu/h 30 41 47
    kW 9 12 14
    Input kW 2.04 3.15 3.64
    COP kW/ kW 4.41 3.81 3.85
    Connectable
    indoor unit
    Total capacity 45~130% of outdoor unit capacity
    Quantity 1~4 1~6 1~7
    Compressor Type DC inverter DC inverter DC inverter
    Quantity 1 1 1
    Oil type RB74AF RB74AF RB74AF
    Fan Motor type DC motor DC motor DC motor
    Quantity 1 1 1
    Output W 80 170 170
    Outdoor air flow m3/h 3700 5200 5000
    Sound pressure level3 dB(A) 54 54 56
    Net dimensions (W×H×D)4 mm 910 x 712 x 426 950 x 840 x 440 950 x 840 x 440
    Packed dimensions (W×H×D) mm 1045 x 810 x 485 1025 x950 x 510 1025 x950 x 510
    Net weight kg 49 59.5 63
    Gross weight kg 53 66.5 70
    Refrigerant Type R410A R410A R410A
    Factory charge g 1700 2300 2400
    Throttle type Electronic expansion valve
    Pipe connections Liquid pipe mm Ф9.53 Ф9.53 Ф9.53
    Gas pipe mm Ф15.9 Ф15.9 Ф15.9
    Ambient Temp.
    operation range
    Cooling oC -5~55
    Heating oC -15~27
    Notes:
    1.      The cooling conditions: indoor temp: 27 oC DB (80.6 oF), 19 oC WB (66.2 oF) outdoor temp: 35 oC DB (95 oF) equivalent pipe length: 5m drop length: 0m.
    2.      The heating conditions: indoor temp: 20 oC DB (68 oF), 15 oC WB (44.6 oF) outdoor temp.: 7 oC DB (42.8 oF) equivalent pipe length: 5m drop length: 0m.
    3.      Sound level: Anechoic chamber conversion value, measured at a point 1 m in front of the unit at a height of 1m for 28/26 model, 1.2m for 42 model. During actual operation, these values are normally somewhat higher as a result of ambient conditions.
    4.      Diameters given are those of the unit's stop valves.
    5.      The above data may be changed without notice for future improvement on quality and performance.
    Model MDV-V48WDHN1(AtB) MDV-V56WDHN1(AtB)
    Power supply V-Ph-Hz 220-240/1/ 50(60)
    Cooling1 Capacity kBtu/h 47 52
    kW 14 15.5
    Input kW 3.97 4.87
    EER kW/ KW 3.53 3.18
    Heating2 Capacity kBtu/h 54 61
    kW 16 18
    Input kW 3.98 4.82
    COP kW/ kW 4.02 3.73
    Connectable
    indoor unit
    Total capacity 45~130% of outdoor unit capacity
    Quantity 1~8 1~9
    Compressor Type DC inverter DC inverter
    Quantity 1 1
    Oil type RB74AF RB74AF
    Fan Motor type DC motor DC motor
    Quantity 1 1
    Output W 170 170
    Outdoor air flow m3/h 5200 5000
    Sound pressure level3 dB(A) 56 56
    Net dimensions (W×H×D)4 mm 950 x 840 x 440 950 x 840 x 440
    Packed dimensions (W×H×D) mm 1025 x950 x 510 1025 x950 x 510
    Net weight kg 75 77.5
    Gross weight kg 82 84.5
    Refrigerant Type R410A R410A
    Factory charge g 3100 3600
    Throttle type Electronic expansion valve
    Pipe connections Liquid pipe mm Ф9.53 Ф9.53
    Gas pipe mm Ф15.9 Ф19.1
    Ambient Temp.
    operation range
    Cooling oC -5~55
    Heating oC -15~27
    Notes:
    1.      The cooling conditions: indoor temp: 27 oC DB (80.6 oF), 19 oC WB (66.2 oF) outdoor temp: 35 oC DB (95 oF) equivalent pipe length: 5m drop length: 0m.
    2.      The heating conditions: indoor temp: 20 oC DB (68 oF), 15 oC WB (44.6 oF) outdoor temp.: 7 oC DB (42.8 oF) equivalent pipe length: 5m drop length: 0m.
    3.      Sound level: Anechoic chamber conversion value, measured at a point 1 m in front of the unit at a height of 1m for 28/26 model, 1.2m for 42 model. During actual operation, these values are normally somewhat higher as a result of ambient conditions.
    4.      Diameters given are those of the unit's stop valves.
    5.      The above data may be changed without notice for future improvement on quality and performance.

    Midea Atom Series Mini VRF

    Introducing Midea Atom Series Mini VRF :

    1. Group control for maximum 9 IDUs
    2. Maximum space usability
    3. Long piping capability for flexible installation
    4. Loop setting of weekly operation schedule
    5. Cloud control
    6. Centralized control