Operating ambient temperatures
Suggested retail price
Technology
Sine-Wave Inverter
Technology 180° -gradusnogo wave inverter conversion - control voltage without the "pulse" effects (jagged sinusoid).
Compared with the current standard of 120° rectangular wave has the following advantages:
- Ability to work with a wider range of supply voltage and frequency.
- Most of the energy efficiency and energy conservation.
- More soft start, lower noise and vibration.
- more control.
Aluminium heat exchanger with hydrophilic coating
Improved wettability of the heat exchanger aluminum plates which have a special coating with a hydrophilic layer, ensuring rapid removal of condensate from the indoor unit that does not allow to quickly form of mold and bacteria, providing a more efficient operation of the air conditioner.
Compresor DC inverter
Compressor with inverter DC can increase the efficiency of the air conditioner, thus reducing power consumption saves your costs. This system is much more economical and safer than air conditioners with a constant output of the compressor.
DC inverter motor Outdoor Unit
In outdoor units, a DC motor is used to rotate the fan. This allows you to significantly reduce noise and power consumption. And also get several positions of the fan speed, depending on the needs of the system.
Multi-Bend Heat Exchanger
Increased heat. This unit uses the heat exchangers with tubes of a special design, the inner surface of which has trapezoidal notches "Innergrove cooper", which provides maximum heat transfer surface area increased. Due to this heat increases by 28%, reduced power consumption, and hence increases the efficiency of the system.
Description
• Budget outdoor units in VRF class;
• Optimal solution for small buildings;
• Long track length;
• Highly efficient compressor DC-Inverter;
• Wide range of 20–33.5 kW;
• G-shaped heat exchanger with hydrophilic coating;
• Updated intelligent control system;
• Fans based on DC motors with improved blade aerodynamics;
• Load range (according to the sum of indices of indoor units) 15–130%;
• Autorestart with restoration of operating parameters, with an oil return cycle;
• Strong protective grille for fans;
• Precise temperature control - by changing the compressor frequency and the EXV multi-position valve.
Specifications
HP | 7 | 8 | 9 | ||||
Model name | MVi-200WV2RN1(A) | MVi-224WV2RN1(A) | MVi-260WV2RN1(A) | ||||
Power supply | V/Ph/Hz | 380-415/3/50 | |||||
Cooling1 | Capacity | kW | 20 | 22.4 | 26.0 | ||
Power input | kW | 5.28 | 6.77 | 10.04 | |||
EER | 3.79 | 3.31 | 2.59 | ||||
Heating2 (Rated) |
Capacity | kW | 20 | 22.4 | 26.0 | ||
Power input | kW | 4.43 | 5.42 | 6.86 | |||
COP | 4.51 | 4.13 | 3.79 | ||||
Heating3 (Max.) | Capacity | kW | 22.5 | 25.0 | 28.5 | ||
Power input | kW | 5.95 | 6.67 | 7.70 | |||
COP | 3.78 | 3.75 | 3.70 | ||||
Connected indoor unit |
Total capacity | 50-130% of outdoor unit capacity | |||||
Maximum quantity | 11 | 13 | 15 | ||||
Compressor | Type | DC inverter rotary | |||||
Quantity | 1 | ||||||
Oil type | RB75EA | ||||||
Start-up method | Soft start | ||||||
Fan | Type | Propeller | |||||
Motor type | DC | ||||||
Quantity | 2 | ||||||
Motor output | kW | 0.17×2 | 0.17×2 | 0.17×2 | |||
Air flow rate | m3/h | 9000 | 9000 | 10000 | |||
Drive type | Direct | ||||||
Refrigerant | Type | R410A | |||||
Factory charge | kg | 6.5 | 6.5 | 6.5 | |||
Pipe connections4 |
Liquid pipe | mm | Ф9.53 | Ф9.53 | Ф9.53 | ||
Gas pipe | mm | Ф19.1 | Ф19.1 | Ф22.2 | |||
Sound pressure level5 | dB(A) | 58 | 58 | 59 | |||
Sound power level5 | dB(A) | 78 | 78 | 78 | |||
Net dimensions (W×H×D) | mm | 1120×1558×528 | |||||
Packed dimensions (W×H×D) | mm | 1270×1720×565 | |||||
Net weight | kg | 143 | 143 | 144 | |||
Gross weight | kg | 159 | 159 | 160 | |||
Ambient Temp. operation range |
Cooling | oC | -5~48 | ||||
Heating | oC | -20~24 | |||||
Notes: | |||||||
1. Indoor temperature 27°C DB, 19°C WB; outdoor temperature 35°C DB; equivalent refrigerant piping length 7.5m with zero level difference. | |||||||
2. Indoor temperature 20°C DB; outdoor temperature 7°C DB, 6°C WB; equivalent refrigerant piping length 7.5m with zero level difference. | |||||||
3. Indoor temperature 20°C DB; outdoor temperature 7°C DB, 6°C WB; equivalent refrigerant piping length 7.5m with zero level difference. | |||||||
4. Diameters given are those of the unit's stop valves. | |||||||
5. Sound pressure level is measured at a position 1m in front of the unit and 1m above the floor in a semi-anechoic chamber. |
HP | 10 | 12 | |||||
Model name | MVi-280WV2RN1(A) | MVi-335WV2RN1(A) | |||||
Power supply | V/Ph/Hz | 380-415/3/50 | |||||
Cooling1 | Capacity | kW | 28.5 | 33.5 | |||
Power input | kW | 12.23 | 15.30 | ||||
EER | 2.33 | 2.19 | |||||
Heating2 (Rated) | Capacity | kW | 28.5 | 33.5 | |||
Power input | kW | 7.68 | 10.15 | ||||
COP | 3.71 | 3.30 | |||||
Heating3 (Max.) | Capacity | kW | 31.5 | 37.5 | |||
Power input | kW | 7.87 | 11.72 | ||||
COP | 4.00 | 3.20 | |||||
Connected indoor unit |
Total capacity | 50-130% of outdoor unit capacity | |||||
Maximum quantity | 16 | 20 | |||||
Compressor | Type | DC inverter rotary | |||||
Quantity | 1 | 1 | |||||
Oil type | RB75EA | FV50S | |||||
Start-up method | Soft start | ||||||
Fan | Type | Propeller | |||||
Motor type | DC | ||||||
Quantity | 2 | ||||||
Motor output | kW | 0.17×2 | 0.17×2 | ||||
Air flow rate | m3/h | 11000 | 11300 | ||||
Drive type | Direct | ||||||
Refrigerant | Type | R410A | |||||
Factory charge | kg | 6.5 | 8 | ||||
Pipe connections4 | Liquid pipe | mm | Φ9.53 | Φ12.7 | |||
Gas pipe | mm | Φ22.2 | Φ25.4 | ||||
Sound pressure level5 | dB(A) | 60 | 61 | ||||
Sound power level5 | dB(A) | 78 | 81 | ||||
Net dimensions (W×H×D) | mm | 1120×1558×528 | |||||
Packed dimensions (W×H×D) | mm | 1270×1720×565 | |||||
Net weight | kg | 144 | 157 | ||||
Gross weight | kg | 160 | 173 | ||||
Ambient Temp. operation range | Cooling | oC | -5~48 | ||||
Heating | oC | -20~24 | |||||
Notes: | |||||||
1. Indoor temperature 27°C DB, 19°C WB; outdoor temperature 35°C DB; equivalent refrigerant piping length 7.5m with zero level difference. | |||||||
2. Indoor temperature 20°C DB; outdoor temperature 7°C DB, 6°C WB; equivalent refrigerant piping length 7.5m with zero level difference. | |||||||
3. Indoor temperature 20°C DB; outdoor temperature 7°C DB, 6°C WB; equivalent refrigerant piping length 7.5m with zero level difference. | |||||||
4. Diameters given are those of the unit's stop valves. | |||||||
5. Sound pressure level is measured at a position 1m in front of the unit and 1m above the floor in a semi-anechoic chamber. |