Midea MCA3(1) DC (2020) MCA-18FNXDO/ MOU-18FN8-RDO air conditioner

Suggested retail price

65 190,-hrv.

Main functions

24-hour timer
3-minute protection feature
Air outlet in all directions
Anti-Cold Air Function
Anti-corrosion coating of the heat exchanger
Auto-restart
Auto-unfreezing
Automatic operation of the horizontal blinds
Built-in drain pump
Chassis Heating Belt
Cooling-Heating
Effective drainage
Fresh Air
IR Remote Control
LED display
Low noise level
Night Mode
Refrigerant Leakage Detect
Self-diagnosis function
Small height of the housing
The central group control panel
WiFi Module
Wired Remote Control

Operating ambient temperatures

Cooling mode
- 15
... + 50 °C
Heating mode
- 15
... + 24 °C
    Technology

    Blue Fin

    Blue fin heat exchanger cover - Protection against corrosion. Special anti-corrosion coating of the heat exchanger, protection from atmospheric phenomena and effects of aggressive environment. May differ in color (have blue, green, gold or no color at all (clear varnish)

    Silence

    The "Silence" - air conditioning reduces the fan speed of the indoor unit to a minimum, with the noise of the air conditioner as well reduced.

    Compresor DC inverter

    Compressor with inverter DC can increase the efficiency of the air conditioner, thus reducing power consumption saves your costs. This system is much more economical and safer than air conditioners with a constant output of the compressor.

    Night Mode

    Mode is activated with the remote control and provides a comfortable environment for a peaceful and deep sleep during the 7-hour cycle with a temperature change of reference values​​, as well as setting the minimum noise level and economical energy consumption. After that, the temperature returns to the originally specified value.

    Refrigerant Leakage Detect

    Its a electronical function of Main PCB and self-diagnostic system into AC.

    When pipe-temperature sensor at inlet line of evaporator will indicate highest temperature, system will indicate "EC" code in a display of indoor units, its mean "ask for service centre for visit maintance team with leakage detectors and tools"

    Ozone-friendly freon R32

    The new refrigerant R32 (difluoromethane) has significant advantages. First of all, it concerns the potential of global warming (GWP). If we compare the highly popular R410A refrigerant with R32, the latter differs by more than 65% of the GWP reduced. It follows that the environment is less affected by the new refrigerant. Also, R32 is characterized by reduced viscosity and density. Due to the lower density, the freon consumption is reduced, taking into account the same power figures. The density of difluoromethane is almost 30% less than that of R410A.

    Low Ambient Cooling

    Low-temperature (season) set - used for the operation of the air conditioner in cooling mode at low ambient temperatures (usually provided in the air conditioner as an optional feature). The kit includes: the controller of the outdoor unit fan motor, compressor crankcase heater and heater drain line.

    In some series of inverter split systems this option is implemented in hardware and software, thus if there is a need to use the air conditioner in the winter for cooling, you must install only drain the heater.

    Crankcase Heater

    To prevent the compressor's hydraulic impact, when the split system is in operation, in the cold season (at negative outdoor temperatures), an electric TEN is installed. The heating element is turned on when the compressor is stopped and does not allow condensed liquid freon in the oil in the compressor crankcase.

    Dry Mode

    Dry mode automatically selects cooling, based on the difference between fixed and temparaturoy actual room temperature. The temperature is regulated while reducing humidity repeated switching on and off of the cooling and ventilation only. when the dry mode on the remote control shows "Drop"

    Multi-Bend Heat Exchanger

    Increased heat. This unit uses the heat exchangers with tubes of a special design, the inner surface of which has trapezoidal notches "Innergrove cooper", which provides maximum heat transfer surface area increased. Due to this heat increases by 28%, reduced power consumption, and hence increases the efficiency of the system.

    Sine-Wave Inverter

    Technology 180° -gradusnogo wave inverter conversion - control voltage without the "pulse" effects (jagged sinusoid).

    Compared with the current standard of 120° rectangular wave has the following advantages:

    1. Ability to work with a wider range of supply voltage and frequency.
    2. Most of the energy efficiency and energy conservation.
    3. More soft start, lower noise and vibration.
    4. more control.

    The Indoor Unit

    Model Name
    MCA-18FNXDO
    Power Options, V/Hz/Ph
    220/50/1

    Power, kW

    Cooling Power
    0.790
    ... 6.150
    Heating Capacity
    0.880
    ... 7.030

    Power consumption, kW

    Cooling
    0.270
    ... 2.370
    Heating
    0.290
    ... 2.510

    Energy Efficiency Class

    Cooling
    A++
    Heating
    при 2℃ - A+++; при -7℃ - A+

    Energy Efficiency Ratio

    SEER (cooling mode)
    6.30
    SCOP (heating mode)
    5.10
    ... 4.00
    Air flow rate, m³/h
    660
    ... 490
    Sound Pressure Level, dB(A)
    46.00
    ... 38.00
    Sound Power Level, dB(A)
    57.00
    Drain pipes diameter, mm
    25 mm

    Panel

    Panels Colour
    White
    Panel Size (WxHxD), mm
    647
    x 50
    x 647
    Panel Weight, kg
    2.50
    Slim air conditioner case
    Yes

    Dimensions(WxHxD), mm

    Without Package
    570
    x 260
    x 570
    in Multiples
    662
    x 317
    x 662

    Weight, kg

    Net Weight
    16.50
    Gross Weight
    19.00

    The outdoor Unit

    Model Name
    MOU-18FN8-RDO (MOB30U-18HFN8-Q)
    Compressors Type
    Inverter
    Compressor
    GMCC ROTARY DC

    Freon

    Freon Type
    R32
    Freon Weight, kg
    1.35, kg
    Power Options, V/Hz/Ph
    220/50/1
    Air flow rate, m3/h
    2,100
    Sound Pressure Level, dB(A)
    57.00
    Sound Power Level, dB(A)
    65.00

    Diameter Pipes, mm

    Liquid
    6.35
    Gas
    12.70
    Min length of main line, m
    3
    Max length of main line, m
    30
    Max vertical drop, m
    20

    Dimensions(WxHxD), mm

    Without Package
    800
    x 554
    x 333
    in Multiples
    920
    x 615
    x 390

    Weight, kg

    Net Weight
    35.60
    Gross Weight
    38.50