Midea "Outdoor units VRF systems V5-X Modular series"

Operating ambient temperatures

Cooling mode
- 5
... + 48 °C
Heating mode
- 20
... + 24 °C

Suggested retail price

282,900- ... 526,850-hrv.

    Sine-Wave Inverter

    Technology 180° -gradusnogo wave inverter conversion - control voltage without the "pulse" effects (jagged sinusoid).

    Compared with the current standard of 120° rectangular wave has the following advantages:

    1. Ability to work with a wider range of supply voltage and frequency.
    2. Most of the energy efficiency and energy conservation.
    3. More soft start, lower noise and vibration.
    4. more control.

    Compresor DC inverter

    Compressor with inverter DC can increase the efficiency of the air conditioner, thus reducing power consumption saves your costs. This system is much more economical and safer than air conditioners with a constant output of the compressor.

    Multi-Bend Heat Exchanger

    Increased heat. This unit uses the heat exchangers with tubes of a special design, the inner surface of which has trapezoidal notches "Innergrove cooper", which provides maximum heat transfer surface area increased. Due to this heat increases by 28%, reduced power consumption, and hence increases the efficiency of the system.

    Maximum capacity of indoor units 64 to 130% of outdoor units "may be combined into a single cooling system. It is especially suitable for office buildings, hotels, apartments, waiting rooms, hospitals and so forth.

    To connect the indoor unit to the grid and connect them to the outdoor unit and the central console, use a 3-wire shielded cable (0.75mm2), which is connected to the terminals with the correct polarity.

    External power can allocate addresses for each indoor unit automatically. However, wired (wireless) controller (RC) can be invited and manually change any address of the indoor unit.

    • The total length of the pipes can be 1000 m
    • Maximum actual length 175 m routes are
    • The maximum equivalent pipe length of 200 m
    • Equivalent length of pipe from the first installed indoors rifneta to the most distant indoor unit - 40/90 (When the equivalent length of pipe from the first installed inside the premises of the splitter to the farthest indoor unit more than 40 m, it must comply with specific conditions in accordance with the technical manual for the equipment)

    Options

    MV5-X252W/V2GN1

    MV5-X280W/V2GN1

    MV5-X335W/V2GN1

    MV5-X400W/V2GN1

    MV5-X450W/V2GN1

    MV5-X500W/V2GN1

    MV5-X560W/V2GN1

    MV5-X615W/V2GN1

    Power supply, V/Hz/Ph

    380/50/3

    380/50/3

    380/50/3

    380/50/3

    380/50/3

    380/50/3

    380/50/3

    380/50/3

    Power

    Cooling,kW

    25.20

    28.00

    33.50

    40.0

    45.0

    50.0

    56.0

    61.5

    Heating,kW

    27.0

    31.5

    37.5

    45.0

    50.0

    56.0

    63.0

    69.0

    Power consumption

    Cooling,kW

    5.79

    7.02

    8.71

    10.81

    12.83

    14.47

    16.67

    18.77

    Heating,kW

    5.79

    7.19

    8.82

    10.98

    12.47

    14.15

    15.98

    17.86

    Refrigerant type

    R410

    R410

    R410

    R410

    R410

    R410

    R410

    R410

    Product dimensions (WxHxD), mm

    990x1635x790

    990x1635x790

    990x1635x790

    1340x1635x790

    1340x1635x790

    1340x1635x790

    1340x1635x790

    1340x1635x790

    Weight, net/gross, kg

    219/234

    219/234

    237/252

    297/315

    297/315

    305/323

    340/358

    340/358

    Airflow, m³/h

    10800

    10800

    10800

    14000

    14000

    15500

    15500

    15500

    The noise level, dB

    43-58

    43-59

    43-60

    43-62

    43-62

    43-63

    43-63

    43-63

    Max. vertical drop, ODU above IDU / ODU below IDU, m

    70/110

    70/110

    70/110

    70/110

    70/110

    70/110

    70/110

    70/110

    The actual length of the piping of the refrigerant circuit, m

    1000

    1000

    1000

    1000

    1000

    1000

    1000

    1000

    Equivalent piping length of the refrigerant circuit, m

    200

    200

    200

    200

    200

    200

    200

    200

    The maximum number of indoor units, pcs.

    13

    16

    19

    23

    26

    29

    33

    36

    Allowable load range in the indices of indoor units,%

    50-130

    50-130

    50-130

    50-130

    50-130

    50-130

    50-130

    50-130