Suggested retail price
Technology
Aluminium heat exchanger with hydrophilic coating
Improved wettability of the heat exchanger aluminum plates which have a special coating with a hydrophilic layer, ensuring rapid removal of condensate from the indoor unit that does not allow to quickly form of mold and bacteria, providing a more efficient operation of the air conditioner.
Central Controller
- The central controller is used for centralized management of indoor units (up to 64 indoor units can be connected via an adapter card).
- The indoor units can be divided into 20 zones, each zone can contain no more than 64 indoor units. All indoor units in one zone can only be set to the same mode. (By default, "the zone is not assigned to indoor units").
- Users can select the desired mode and temperature with a weekly schedule.
Dry Mode
Dry mode automatically selects cooling, based on the difference between fixed and temparaturoy actual room temperature. The temperature is regulated while reducing humidity repeated switching on and off of the cooling and ventilation only. when the dry mode on the remote control shows "Drop"
Motor DC inverter indoor unit
The indoor unit is used to rotate the impeller DC - motor. This can significantly reduce noise and power consumption. And also get 12 positions change the speed of the impeller.
Multi-Bend Heat Exchanger
Increased heat. This unit uses the heat exchangers with tubes of a special design, the inner surface of which has trapezoidal notches "Innergrove cooper", which provides maximum heat transfer surface area increased. Due to this heat increases by 28%, reduced power consumption, and hence increases the efficiency of the system.
Night Mode
Mode is activated with the remote control and provides a comfortable environment for a peaceful and deep sleep during the 7-hour cycle with a temperature change of reference values, as well as setting the minimum noise level and economical energy consumption. After that, the temperature returns to the originally specified value.
Turbo
Tthe «Turbo» function - when you turn on this mode, air conditioning provides the most rapid cooling or heating, to create comfortable conditions in the shortest possible time.
Description
- M9 panel
- Built-in EXV valve.
- 2 directions of the output of the freon pipes and the drainage pipe - to the side (to the right to the left, if you look at the block from the front), or down.
Specifications
Model | MI-22G/DHN1-M | MI-28G/DHN1-M | MI-36G/DHN1-M | MI-45G/DHN1-M | ||
Power supply | V- Ph-Hz | 220-240V~50Hz | ||||
Cooling | Capacity | kW | 2.2 | 2.8 | 3.6 | 4.5 |
Input | W | 8 | 9 | 19 | 19 | |
Rated current | A | 0.27 | 0.31 | 0.43 | 0.44 | |
Heating | Capacity | kW | 2.4 | 3.2 | 4 | 5 |
Input | W | 8 | 9 | 19 | 19 | |
Rated current | A | 0.27 | 0.31 | 0.43 | 0.44 | |
Indoor fan motor | Model | WZDK20-38G | WZDK20-38G | ZKSP-58-8-1 | ZKSP-58-8-1 | |
Type | DC motor | |||||
Input | W | 7 | 8 | 18 | 18 | |
Indoor coil | Number of rows | 1 | 2 | 1 | 2 | |
Tube pitch× row pitch |
mm | 21×13.37 | ||||
Fin spacing | mm | 1.3 | ||||
Fin type | Hydrophilic aluminum | |||||
Piping diameter | mm | Ф7 | ||||
Length× height | mm | 585×315 | 585×315 | 701×315 | 701×315 | |
Number of circuits | 2 | 3 | 3 | 5 | ||
Indoor air flow (H/M/L) | m3/h | 422/393/356 | 417/370/316 | 656/573/488 | 594/507/424 | |
Indoor noise level (H/M/L) | dB(A) | 31/30/29 | 31/30/29 | 33/32/30 | 35/33/31 | |
Indoor unit | Dimension (W×H×D) | mm | 835×280×203 | 835×280×203 | 990×315×223 | 990×315×223 |
Packing (W×H×D) | mm | 935×385×320 | 935×385×320 | 1085×420×335 | 1085×420×335 | |
Net/Gross weight | kg | 8.4/12.1 | 9.5/13.1 | 11.4/15.5 | 12.8/16.9 | |
Refrigerant type | R410A | |||||
Throttle | Type | Electronic expansion valve | ||||
Design pressure (H/L) | MPa | 4.4/2.6 | ||||
Liquid pipe/ Gas pipe | mm | Ф6.35/ Ф12.7 | ||||
Connecting wiring | Power wiring | mm2 | 3×2.5 | |||
Signal wiring | mm2 | 3×0.75 | ||||
Drainage water pipe diameter | mm | Ф16.5 | ||||
Controller | Wireless remote controller | |||||
Notes: | ||||||
Nominal cooling capacities are based on the following conditions: return air temperature: 27°CDB, 19°CWB; outdoor temperature: 35°CDB, equivalent ref. piping: 8m (horizontal) | ||||||
Nominal heating capacities are based on the following conditions: return air temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB; | ||||||
equivalent ref. piping: 8m (horizontal) |
Model | MI-56G/DHN1-M | MI-71G/DHN1-M | MI-80G/DHN1-M | MI-90G/DHN1-M | ||
Power supply | V- Ph-Hz | 220-240V~50Hz | ||||
Cooling | Capacity | kW | 5.6 | 7.1 | 8 | 9 |
Input | W | 27 | 49 | 53 | 82 | |
Rated current | A | 0.58 | 0.6 | 0.6 | 0.78 | |
Heating | Capacity | kW | 6.3 | 8 | 9 | 10 |
Input | W | 27 | 49 | 53 | 80 | |
Rated current | A | 0.58 | 0.6 | 0.6 | 0.78 | |
Indoor fan motor | Model | ZKSP-58-8-1 | ZKSP-60-8-3 | ZKSP-60-8-3 | ZKSP-60-8-3 | |
Type | DC motor | |||||
Input | W | 25 | 40 | 40 | 65 | |
Indoor coil | Number of rows | 2 | 2 | 2 | 2 | |
Tube pitch× row pitch |
mm | 21×13.37 | ||||
Fin spacing | mm | 1.3 | ||||
Fin type | Hydrophilic aluminum | |||||
Piping diameter | mm | Ф7 | ||||
Length× height | mm | 701×315 | 825×399 | 825×399 | 825×399 | |
Number of circuits | 5 | |||||
Indoor air flow (H/M/L) | m3/h | 747/648/547 | 1195/1005/809 | 1195/1005/809 | 1421/1067/867 | |
Indoor noise level (H/M/L) | dB(A) | 38/36/34 | 44/39/36 | 44/39/36 | 48/43/38 | |
Indoor unit | Dimension (W×H×D) | mm | 990×315×223 | 1194×343×262 | 1194×343×262 | 1194×343×262 |
Packing (W×H×D) | mm | 1085×420×335 | 1290×375×460 | 1290×375×460 | 1290×375×460 | |
Net/Gross weight | kg | 12.8/16.9 | 17/22.4 | 17/22.4 | 17/22.4 | |
Refrigerant type | R410A | |||||
Throttle | Type | Electronic expansion valve | ||||
Design pressure (H/L) | MPa | 4.4/2.6 | ||||
Liquid pipe/ Gas pipe | mm | Ф9.53/ Ф15.9 | ||||
Connecting wiring | Power wiring | mm2 | 3×2.5 | |||
Signal wiring | mm2 | 3×0.75 | ||||
Drainage water pipe diameter | mm | Ф16.5 | ||||
Controller | Wireless remote controller | |||||
Notes: | ||||||
Nominal cooling capacities are based on the following conditions: return air temperature: 27°CDB, 19°CWB; outdoor temperature: 35°CDB, equivalent ref. piping: 8m (horizontal) | ||||||
Nominal heating capacities are based on the following conditions: return air temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB; | ||||||
equivalent ref. piping: 8m (horizontal) |