Midea "M5OE-42HFN1-Q" series

Operating ambient temperatures

Cooling mode
- 15
... + 50 °C
Heating mode
- 15
... + 24 °C

Suggested retail price

87,330-hrv.

    Compresor DC inverter

    Compressor with inverter DC can increase the efficiency of the air conditioner, thus reducing power consumption saves your costs. This system is much more economical and safer than air conditioners with a constant output of the compressor.

    Outdoor unit design "Brilliant"

    Designers Midea did not forget about the exterior of the exterior unit of the air conditioner, which in itself is a rarity for climate technology. The outdoor unit is much more elegant than its counterparts, it has facets like a diamond, and attention to detail speaks of a high level of production and a carefully thought-out design concept.

    Low Ambient Cooling

    Low-temperature (season) set - used for the operation of the air conditioner in cooling mode at low ambient temperatures (usually provided in the air conditioner as an optional feature). The kit includes: the controller of the outdoor unit fan motor, compressor crankcase heater and heater drain line.

    In some series of inverter split systems this option is implemented in hardware and software, thus if there is a need to use the air conditioner in the winter for cooling, you must install only drain the heater.

    Multi-Bend Heat Exchanger

    Increased heat. This unit uses the heat exchangers with tubes of a special design, the inner surface of which has trapezoidal notches "Innergrove cooper", which provides maximum heat transfer surface area increased. Due to this heat increases by 28%, reduced power consumption, and hence increases the efficiency of the system.

    Sine-Wave Inverter

    Technology 180° -gradusnogo wave inverter conversion - control voltage without the "pulse" effects (jagged sinusoid).

    Compared with the current standard of 120° rectangular wave has the following advantages:

    1. Ability to work with a wider range of supply voltage and frequency.
    2. Most of the energy efficiency and energy conservation.
    3. More soft start, lower noise and vibration.
    4. more control.

    A wide range of indoor units by type and performance.

    Up to 5 indoor units of various types (wall, cassette 600х600, channel and floor-ceiling) can be connected to multisystems.
    Simultaneously, the units can operate only in one mode - cooling or heating, but in each room it is possible to set and maintain individual air parameters. DC inverter control of the compressor motor and outdoor fan provides high energy efficiency and economy of the system.

    Possible combinations of indoor units for outdoor multisystem units.
    This series of multi-split systems is assembled as a "designer" - i.e. Different internal units are connected to one outdoor unit in certain combinations by power indices, while the type and design of indoor units is not limited and is chosen according to the client's desire.
    The combinations of the connected indoor units can only be performed in accordance with the tables given.

    Outdoor Model  M5OE-42HFN1-Q 
    Outdoor Model NEW  M5O-42FN1-Q 
    Indoor unit combination Single Double Three Four MA-09N1D0-I
    MSMAAU-09HRDN1
    upply V,Hz,Ph 220-240V,50Hz, 1Ph
    Cooling Capacity                      Btu/h 7000-18000 14000-28000 21000-36000 28000-40000 42000
    nput            W 680-1800 1400-2780 2100-3450 2700-3700 4380
    Rated current    A 3.0-8.0 6.2-11.8 9.0-15.0 11.6-16.0 19
    Heating Capacity         Btu/h 8000-20000 14000-28000 21000-36000 28000-40000 42000
    nput            W 680-1800 1400-2680 1995-3330 2580-3570 4089
    Rated current    A 3.0-8.0 6.2-11.3 8.5-14.5 11.1-15.8 17,7
    Seasonal Cooling Pdesignc kW 12,3
    SEER W/W 6,1
    Energy Efficiency Class   A++
    Heating(Average) Pdesignh kW 9,5
    SCOP W/W 3,4
    Energy Efficiency Class   A
    Tbiv -7
    Tol -15
    Max. input consumption         W 4700
    Max. input current              A 22
    Compressor Model    ATF310D43UMT
    Type    ROTARY
    Brand    GMCC
    Capacity      Btu/h 32380
    Input           W 2600
    Rated current(RLA)  A 5,1
    Thermal protector position   INTERNAL
    Refrigerant oil    ml PQE(VG74)/1000
    Outdoor fan motor New Model    ZKFN-120-8-2
    Model    WZDK120-38G-W
    Qty    1
    Output W 120(Output)
    Speed(Hi/Med/Lo) r/min 900
    Outdoor coil Number of rows   2,6
    Tube pitch(a)* row pitch(b)  mm 25.4x22
    Fin spacing mm 1,3
    Fin type    Hydrophilic aluminium
    Tube outside dia.and type  mm Φ9.52,innergroove tube
    Coil length * height * width mm 978x762x44+580x762x22
    Number of circuits   4
    Outdoor air flow             m3/h 5500
    Indoor sound power level  dB(A) 58
    Outdoor  sound pressure level dB(A) 64
    Outdoor sound power level  dB(A) 68
    Throttle type   Capillary+EXV
    Outdoor unit Dimension(WxDxH) mm 946x410x810
    Packing(WxDxH) mm 1090x500x875
    Net/Gross weight   kg 76/81
    Refrigerant           Type    R410A
    GWP   2088
    Charged quantity Kg 3,6
    Design pressure MPa 4.2/1.5
    Refrigerant piping Liquid side/ Gas side   mm (inch) 5 x Φ6.35/4x Φ9.52+1xΦ12.7(5x1/4"/4x3/8"+1x1/2")
    Max. length for all rooms m 80
    Max. length for one indoor unit m 35
    Max. height difference between indoor and outdoor unit  m 15
    Max. height difference between indoor units  m 10
    Ambient temperature Cooling -15-50
    Heating -15-24
    Remarks:                        
    1.The above design and specifications are subject to change without prior notice for product improvement.            
    2.The values given in the table for the noise level reflect the levels in hemi-anechoic rooms.