Midea MTI DC MTI-55HWFNX-QW /MOU1-55HFN8-RR air conditioner

Suggested retail price

148 625,-hrv.

Main functions

2-way Draining
24-hour timer
3-minute protection feature
Anti-Cold Air Function
Anti-corrosion coating of the heat exchanger
Auto-restart
Auto-unfreezing
Cooling-Heating
Effective drainage
Fresh Air
IR Remote Control
LED display
Low noise level
Night Mode
Self-diagnosis function
Small height of the housing
Built-in drain pump
The central group control panel
WiFi Module
Wired Remote Control

Operating ambient temperatures

Cooling mode
- 15
... + 50 °C
Heating mode
- 25
... + 24 °C
    Technology

    Blue Fin

    Blue fin heat exchanger cover - Protection against corrosion. Special anti-corrosion coating of the heat exchanger, protection from atmospheric phenomena and effects of aggressive environment. May differ in color (have blue, green, gold or no color at all (clear varnish)

    Central Controller

    1. The central controller is used for centralized management of indoor units (up to 64 indoor units can be connected via an adapter card).
    2. The indoor units can be divided into 20 zones, each zone can contain no more than 64 indoor units. All indoor units in one zone can only be set to the same mode. (By default, "the zone is not assigned to indoor units").
    3. Users can select the desired mode and temperature with a weekly schedule.

    Compresor DC inverter

    Compressor with inverter DC can increase the efficiency of the air conditioner, thus reducing power consumption saves your costs. This system is much more economical and safer than air conditioners with a constant output of the compressor.

    Dry Mode

    Dry mode automatically selects cooling, based on the difference between fixed and temparaturoy actual room temperature. The temperature is regulated while reducing humidity repeated switching on and off of the cooling and ventilation only. when the dry mode on the remote control shows "Drop"

    Low Ambient Cooling

    Low-temperature (season) set - used for the operation of the air conditioner in cooling mode at low ambient temperatures (usually provided in the air conditioner as an optional feature). The kit includes: the controller of the outdoor unit fan motor, compressor crankcase heater and heater drain line.

    In some series of inverter split systems this option is implemented in hardware and software, thus if there is a need to use the air conditioner in the winter for cooling, you must install only drain the heater.

    Multi-Bend Heat Exchanger

    Increased heat. This unit uses the heat exchangers with tubes of a special design, the inner surface of which has trapezoidal notches "Innergrove cooper", which provides maximum heat transfer surface area increased. Due to this heat increases by 28%, reduced power consumption, and hence increases the efficiency of the system.

    Night Mode

    Mode is activated with the remote control and provides a comfortable environment for a peaceful and deep sleep during the 7-hour cycle with a temperature change of reference values​​, as well as setting the minimum noise level and economical energy consumption. After that, the temperature returns to the originally specified value.

    Ozone-friendly freon R32

    The new refrigerant R32 (difluoromethane) has significant advantages. First of all, it concerns the potential of global warming (GWP). If we compare the highly popular R410A refrigerant with R32, the latter differs by more than 65% of the GWP reduced. It follows that the environment is less affected by the new refrigerant. Also, R32 is characterized by reduced viscosity and density. Due to the lower density, the freon consumption is reduced, taking into account the same power figures. The density of difluoromethane is almost 30% less than that of R410A.

    Silence

    The "Silence" - air conditioning reduces the fan speed of the indoor unit to a minimum, with the noise of the air conditioner as well reduced.

    Sine-Wave Inverter

    Technology 180° -gradusnogo wave inverter conversion - control voltage without the "pulse" effects (jagged sinusoid).

    Compared with the current standard of 120° rectangular wave has the following advantages:

    1. Ability to work with a wider range of supply voltage and frequency.
    2. Most of the energy efficiency and energy conservation.
    3. More soft start, lower noise and vibration.
    4. more control.

    Temperature compensation

    The function of temperature compensation corrects the temperature in the person's zone of being comfortable, (because the air temperature near the floor and ceiling can differ by several degrees) by further increasing / decreasing the temperature from the value set from the remote control. Thus, compensation and equalization of the overall room temperature occurs. For household split systems, the value is set by the manufacturer and is 2°C.

    The Indoor Unit

    Model Name
    MTI-55HWFNX-QW
    Power Options, V/Hz/Ph
    220/50/1

    Power, kW

    Cooling Power
    4.100
    ... 17.290
    Heating Capacity
    4.400
    ... 20.520

    Power consumption, kW

    Cooling
    1.030
    ... 6.650
    Heating
    0.950
    ... 6.600

    Energy Efficiency Class

    Cooling
    A++
    Heating
    при 2℃ - A+++; при -7℃ - A+

    Energy Efficiency Ratio

    SEER (cooling mode)
    6.10
    SCOP (heating mode)
    4.00
    ... 5.10
    Static pressure is nominal (Rated), Pa
    50
    Static pressure, range (Range), Pa
    0.00
    ... 160.00
    Air flow rate, m³/h
    2,600
    ... 1,820
    Sound Pressure Level, dB(A)
    52.50
    ... 47.00
    Sound Power Level, dB(A)
    66.00
    Drain pipes diameter, mm
    25 mm
    Slim air conditioner case
    Yes

    Dimensions(WxHxD), mm

    Without Package
    1200
    x 300
    x 874
    in Multiples
    1405
    x 365
    x 915

    Weight, kg

    Net Weight
    47.40
    Gross Weight
    56.10

    The outdoor Unit

    Model Name
    MOU1-55HFN8-RR
    Compressors Type
    Inverter
    Compressor
    GMCC ROTARY DC

    Freon

    Freon Type
    R32
    Freon Weight, kg
    3.00, kg
    Power Options, V/Hz/Ph
    380/50/3
    Air flow rate, m3/h
    7,500
    Sound Power Level, dB(A)
    73.00

    Diameter Pipes, mm

    Liquid
    9.52
    Gas
    15.90
    Min length of main line, m
    3
    Max length of main line, m
    75
    Max vertical drop, m
    30

    Dimensions(WxHxD), mm

    Without Package
    952
    x 1333
    x 415
    in Multiples
    1095
    x 1480
    x 495

    Weight, kg

    Net Weight
    107.00
    Gross Weight
    121.20