Main functions
Operating ambient temperatures
Duct blocks on the A6 chassis are low-profile, with a height of 210, 249, 300 mm. The design of the blocks allows easy access to all components through the extended side panel or from the lower hatch. Fan motors and impellers provide strong airflow without making excessive noise.
Technology
Blue Fin
Blue fin heat exchanger cover - Protection against corrosion. Special anti-corrosion coating of the heat exchanger, protection from atmospheric phenomena and effects of aggressive environment. May differ in color (have blue, green, gold or no color at all (clear varnish)
Silence
The "Silence" - air conditioning reduces the fan speed of the indoor unit to a minimum, with the noise of the air conditioner as well reduced.
Aluminium heat exchanger with hydrophilic coating
Improved wettability of the heat exchanger aluminum plates which have a special coating with a hydrophilic layer, ensuring rapid removal of condensate from the indoor unit that does not allow to quickly form of mold and bacteria, providing a more efficient operation of the air conditioner.
Flexible Air Intake Ways
Air inlet from back standard and from bottom optional. The size of the plate from bottom and flange from back is the same, it’s easy for installer to change the air inlet from back to bottom.
Wired remote control for indoor unit
The internal block is completed / can be completed (option) with the wire control panel.
General functional features:
- Connection to indoor units using stranded wire.
- The job modes.3. Set the fan speed.
- Display information about operating modes on the LCD.
- Setting the time of automatic on / off using a timer.
Wi-Fi Control (Wi-Fi stick)
Mission's Wi-Fi and Smart Kits* are designed for even more comfortable and easy operation (for some series of Wi-Fi stick - option).
Customers can download absolutely free app for your smartphone with the QR-code located in the user's manual.
Night Mode
Mode is activated with the remote control and provides a comfortable environment for a peaceful and deep sleep during the 7-hour cycle with a temperature change of reference values, as well as setting the minimum noise level and economical energy consumption. After that, the temperature returns to the originally specified value.
The mixing of fresh air
Organization of fresh air - by a separate duct (in a split system with such a function, the duct is usually a small diameter and is laid along the highway) ...
Dry Mode
Dry mode automatically selects cooling, based on the difference between fixed and temparaturoy actual room temperature. The temperature is regulated while reducing humidity repeated switching on and off of the cooling and ventilation only. when the dry mode on the remote control shows "Drop"
Temperature compensation
The function of temperature compensation corrects the temperature in the person's zone of being comfortable, (because the air temperature near the floor and ceiling can differ by several degrees) by further increasing / decreasing the temperature from the value set from the remote control. Thus, compensation and equalization of the overall room temperature occurs. For household split systems, the value is set by the manufacturer and is 2°C.
Multi-Bend Heat Exchanger
Increased heat. This unit uses the heat exchangers with tubes of a special design, the inner surface of which has trapezoidal notches "Innergrove cooper", which provides maximum heat transfer surface area increased. Due to this heat increases by 28%, reduced power consumption, and hence increases the efficiency of the system.
Low Ambient Cooling
Low-temperature (season) set - used for the operation of the air conditioner in cooling mode at low ambient temperatures (usually provided in the air conditioner as an optional feature). The kit includes: the controller of the outdoor unit fan motor, compressor crankcase heater and heater drain line.
In some series of inverter split systems this option is implemented in hardware and software, thus if there is a need to use the air conditioner in the winter for cooling, you must install only drain the heater.
Reserved ON-OFF and Alarm Ports
ON-OFF Switch: With the reserved ports, a remote switch can be easily connected to a realize remote control. Alarm Port: The built-in PCB can output alarm signal, which makes setting up an external alarm light or vibration gauge possible.