Midea "One Way Cassette Indoor Units ATOM Series"

Suggested retail price

14,965- ... 21,730-hrv.

    Night Mode

    Mode is activated with the remote control and provides a comfortable environment for a peaceful and deep sleep during the 7-hour cycle with a temperature change of reference values​​, as well as setting the minimum noise level and economical energy consumption. After that, the temperature returns to the originally specified value.

    Dry Mode

    Dry mode automatically selects cooling, based on the difference between fixed and temparaturoy actual room temperature. The temperature is regulated while reducing humidity repeated switching on and off of the cooling and ventilation only. when the dry mode on the remote control shows "Drop"

    Multi-Bend Heat Exchanger

    Increased heat. This unit uses the heat exchangers with tubes of a special design, the inner surface of which has trapezoidal notches "Innergrove cooper", which provides maximum heat transfer surface area increased. Due to this heat increases by 28%, reduced power consumption, and hence increases the efficiency of the system.

    The Mini VRF ATOM split system has special indoor units. They can only be connected to this system. There are six such blocks, their power is from 2.2 to 16 kW. The new line contains all types of air conditioners.

    The ATOM series includes inverter-type outdoor units with power from 8 kW to 16 kW. The equipment is powered from a single-phase 220V network, which creates certain conveniences when installing air conditioners in private homes or small offices in the central part of the metropolis. ATOM single fan outdoor units are compact and easy to install.

    Installation of the ATOM series multi-zone system can be reduced in cost if the pipes of the interconnecting main are connected using manifold splitter kits. They have from 2 to 6 connection points, and are able to include indoor units of any type in the system. This finding speeds up the installation process, which will be highly appreciated by the customer.

    The indoor units and the air conditioning system can be controlled using:

        - IR remote control RM05B(A);
        - Wired remote control WDC-86E/KD;
        - Touch panels CCM-180A;
        - By connecting to BMS using MODbus protocol.

    Модель внутреннего блока
    MDV-D09Q1/ N1-D(At) MDV-D12Q1/ N1-D(At) MDV-D18Q1/ N1-D(At) MDV-D24Q1/ N1-D(At)
    Панель
    MDV-MBQ1-02D MDV-MBQ1-02D MDV-MBQ1-01D MDV-MBQ1-01D
    Холодопроизводительность, кВт
    2,8 3,6 5,6 7,1
    Теплопроизводительность, кВт
    3,2 4,0 6,3 8,0
    Электропитание, В/Гц/Ф
    220-240/50/1 220-240/50/1 220-240/50/1 220-240/50/1
    Охлаждение: Номинальная потребляемая мощность, кВт
    0,041 0,041 0,048 0,06
    Нагрев: Номинальная потребляемая мощность, кВт
    0,041 0,041 0,048 0,06
    Расход воздуха, м3/ч
    573/456/315 573/456/315 792/688/549 933/749/592
    Уровень шума, дБ(A)
    39/37/34 39/37/34 42/40/36 44/41/37
    Тип хладагента
    R410A R410A R410A R410A
    Размер внутреннего блока (Ш×В×Г), мм
    1054×153×425 1054×153×425 1275×189×450 1275×189×450
    Размер панели (Ш×В×Г), мм
    1180×25×465 1180×25×465 1350×25×505 1350×25×505
    Размер внутреннего блока в упаковке (Ш×В×Г), мм
    1155×245×490 1155×245×490 1370×295×505 1370×295×505
    Размер панели в упаковке (Ш×В×Г), мм
    1232×107×517 1232×107×517 1410×95×560 1410×95×560
    Вес внутреннего блока (нетто/брутто), кг
    13 / 16,5 13 / 16,5 18,8 / 23,1 19,5 / 23,8
    Вес панели (нетто/брутто), кг
    3,5 / 5,2 3,5 / 5,2 4 / 5,4 4 / 5,4
    Диаметр жидкостной трубы, мм (дюйм)
    6,35 (1/4") 6,35 (1/4") 9,53 (3/8") 9,53 (3/8")
    Диаметр газовой трубы, мм (дюйм)
    12,7 (1/2") 12,7 (1/2") 15,88 (5/8") 15,88 (5/8")
    Наружный диаметр отвода дренажа, мм
    25 25 25 25

    Midea Atom Series Mini VRF

    Introducing Midea Atom Series Mini VRF :

    1. Group control for maximum 9 IDUs
    2. Maximum space usability
    3. Long piping capability for flexible installation
    4. Loop setting of weekly operation schedule
    5. Cloud control
    6. Centralized control