Operating ambient temperatures
Suggested retail price
Technology
Aluminium heat exchanger with hydrophilic coating
Improved wettability of the heat exchanger aluminum plates which have a special coating with a hydrophilic layer, ensuring rapid removal of condensate from the indoor unit that does not allow to quickly form of mold and bacteria, providing a more efficient operation of the air conditioner.
DC inverter motor Outdoor Unit
In outdoor units, a DC motor is used to rotate the fan. This allows you to significantly reduce noise and power consumption. And also get several positions of the fan speed, depending on the needs of the system.
Low Ambient Cooling
Low-temperature (season) set - used for the operation of the air conditioner in cooling mode at low ambient temperatures (usually provided in the air conditioner as an optional feature). The kit includes: the controller of the outdoor unit fan motor, compressor crankcase heater and heater drain line.
In some series of inverter split systems this option is implemented in hardware and software, thus if there is a need to use the air conditioner in the winter for cooling, you must install only drain the heater.
Multi-Bend Heat Exchanger
Increased heat. This unit uses the heat exchangers with tubes of a special design, the inner surface of which has trapezoidal notches "Innergrove cooper", which provides maximum heat transfer surface area increased. Due to this heat increases by 28%, reduced power consumption, and hence increases the efficiency of the system.
Sine-Wave Inverter
Technology 180° -gradusnogo wave inverter conversion - control voltage without the "pulse" effects (jagged sinusoid).
Compared with the current standard of 120° rectangular wave has the following advantages:
- Ability to work with a wider range of supply voltage and frequency.
- Most of the energy efficiency and energy conservation.
- More soft start, lower noise and vibration.
- more control.
Description
• Single-fan outdoor units of mini-VRF systems are supplied in a power range of 8-16 kW, with a 220V power supply.
• Ideal for installation in modern high-rise construction, when the developer offers 1–2 points on the facade for mounting an outdoor unit, but at the same time, for comfort, it must have sufficient power and the ability to connect from 3 to 8 indoor units.
• The new series of outdoor units has a tangible gain in terms of size and ease of installation, a more modern electronic power control system, with other characteristics comparable to the previous series.
Specifications
Sale Model | MDV‐V80W/DN1(C) | MDV‐V100W/DN1(C) | MDV‐V120W/DN1(C) | ||
Power supply | V‐Ph‐Hz | 220‐240V~50Hz | 220‐240V~50Hz | 220‐240V~50Hz | |
Cooling | Capacity | kW | 7.2(1.5‐8) | 9(2‐10) | 12.2 |
Input | kW | 2.18 | 2.64 | 4.32 | |
EER | kW/ KW | 3.30 | 3.41 | 2.83 | |
Heating | Capacity | kW | 7.2(1.6‐9) | 9(2.1‐12) | 14 |
Input | kW | 1.82 | 2.12 | 3.17 | |
COP | kW/ kW | 3.95 | 4.29 | 4.40 | |
Compressor | Model | KTM240D57UMT | KTM240D57UMT | ATF400D64UMT | |
Type | Rotary | Rotary | Rotary | ||
Brand | GMCC | GMCC | GMCC | ||
Capacity | Btu/h | 26349 | 26349 | 41957 | |
Input | W | 2085 | 2085 | 3365 | |
Rated current(RLA) | A | 9.45 | 9.45 | 6.5 | |
Crankcase | W | 20 | 20 | 25 | |
Refrigerant oil | ml | RB74AF | RB74AF | RB74AF | |
670ml+0ml | 670ml+200ml | 1000ml+200ml | |||
Outdoor fan motor | Model | WZDK80‐38G‐W(A) | WZDK170‐38G‐1 | WZDK170‐38G‐1 | |
Type | DC motor | DC motor | DC motor | ||
Brand | Welling/NIDEC | Welling/Panasonic/NIDEC | Welling/Panasonic/NIDEC | ||
Insulation class | E | E | E | ||
Safe class | IPX4 | IPX4 | IPX4 | ||
Input | W | 120 | 195 | 195 | |
Output | W | 80 | 170 | 170 | |
Rated current | A | 1 | 1.52 | 1.52 | |
Speed | r/min | 900 | 800 | 800 | |
Outdoor air flow | m3/h | 3700 | 5200 | 5000 | |
Outdoor sound level |
sound pressure level | dB(A) | 54 | 54 | 56 |
Sound power level | dB(A) | 65 | 68 | 70 | |
Outdoor Unit | Dimension(W x H x D) | mm | 910 x 712 x 345 | 950 x 840 x 360 | 950 x 840 x 360 |
Packing (W x H x D) | mm | 1045 x 800 x 485 | 1025 x 860 x 510 | 1025 x 860 x 510 | |
Net/Gross weight | kg | 55/57.5 | 72.5/81 | 84/92 | |
Refrigerant | Type | R410A | R410A | R410A | |
Charged volume | g | 2200 | 2350 | 3000 | |
Throttle type | Electronic expansion valve | ||||
Design pressure | MPa | 4.4/2.6 | |||
Refrigerant piping | Liquid side/ Gas side | mm | Ф9.53/Ф15.9 | Ф9.53/Ф15.9 | Ф9.53/Ф15.9 |
Total Pipe | m | 50 | 65 | ||
Length(Actual) | |||||
Outdoor unit up | Max.difference in level |
10m | 20m | ||
Outdoor unit down | 10m | 20m | |||
Connection wiring |
Power wiring | mm2 | 3*4.0 | ||
Signal wiring | mm2 | 3 core shielded wire x 0.75 | |||
Ambient temp | ℃ | Cooling: ‐5~55, Heating: ‐15~27 | |||
Notes: | |||||
1. The cooling conditions: indoor temp: 27℃DB (80.6℉), 19℃WB (66.2℉) outdoor temp: 35℃DB (95℉) equivalent pipe length: 5m drop | |||||
length: 0m. | |||||
2. The heating conditions: indoor temp: 20℃DB (68℉), 15℃WB (44.6℉) outdoor temp.: 7℃DB (42.8℉) equivalent pipe length: 5m drop | |||||
length: 0m. | |||||
3. Sound level: Anechoic chamber conversion value, measured at a point 1 m in front of the unit at a height of *m(1m for 80/105 model,1.2m | |||||
for 120~160 model). During actual operation, these values are normally somewhat higher as a result of ambient conditions. | |||||
4. The above data may be changed without notice for future improvement on quality and performance. |
Sale Model | MDV‐V140W/DN1(C) | MDV‐V160W/DN1(C) | ||
Power supply | V‐Ph‐Hz | 220‐240V~50Hz | 220‐240V~50Hz | |
Cooling | Capacity | kW | 14 | 15.5 |
Input | kW | 4.56 | 5.35 | |
EER | kW/ KW | 3.07 | 2.90 | |
Heating | Capacity | kW | 16 | 18 |
Input | kW | 4.08 | 5.71 | |
COP | kW/ kW | 3.92 | 3.20 | |
Compressor | Model | ATF400D64UMV | ||
Type | Rotary | Rotary | ||
Brand | GMCC | GMCC | ||
Capacity | Btu/h | 41957 | 41957 | |
Input | W | 3365 | 3365 | |
Rated current(RLA) | A | 6.5 | 6.5 | |
Crankcase | W | 25 | 25 | |
Refrigerant oil | ml | RB74AF | RB74AF | |
1000ml+400ml | 1000ml+500ml | |||
Outdoor fan motor | Model | WZDK170‐38G‐1 | WZDK170‐38G‐1 | |
Type | DC motor | DC motor | ||
Brand | Welling/Panasonic/NIDEC | |||
Insulation class | E | E | ||
Safe class | IPX4 | IPX4 | ||
Input | W | 195 | 195 | |
Output | W | 170 | 170 | |
Rated current | A | 1.52 | 1.52 | |
Speed | r/min | 800 | 800 | |
Outdoor air flow | m3/h | 5400 | 5200 | |
Outdoor sound level | Sound pressure level | dB(A) | 56 | 56 |
Sound power level | dB(A) | 71 | 71 | |
Outdoor Unit | Dimension(W x H x D) | mm | 1040 x 865 x 410 | 1040 x 865 x 410 |
Packing (W x H x D) | mm | 1120 x 890 x 560 | 1120 x 890 x 560 | |
Net/Gross weight | kg | 91.4/100.4 | 95.4/104.4 | |
Refrigerant | Type | R410A | R410A | |
Charged volume | g | 3400 | 3800 | |
Throttle type | Electronic expansion valve | |||
Design pressure | MPa | 4.4/2.6 | ||
Refrigerant piping | Liquid side/ Gas side | mm | Ф9.53/Ф15.9 | Ф9.53/Ф15.9 |
Total Pipe | m | 100 | 100 | |
Length(Actual) | ||||
Outdoor unit up | Max.difference in level |
30m | 30m | |
Outdoor unit down | 20m | 20m | ||
Connection wiring | Power wiring | mm2 | 3*6.0 | 3*6.0 |
Signal wiring | mm2 | 3 core shielded wire x 0.75 |
3 core shielded wire x 0.75 |
|
Ambient temp | ℃ | Cooling: ‐5~55, Heating: ‐15~27 | ||
Notes: | ||||
1. The cooling conditions: indoor temp: 27℃DB (80.6℉), 19℃WB (66.2℉) outdoor temp: 35℃DB (95℉) equivalent pipe length: 5m drop | ||||
length: 0m. | ||||
2. The heating conditions: indoor temp: 20℃DB (68℉), 15℃WB (44.6℉) outdoor temp.: 7℃DB (42.8℉) equivalent pipe length: 5m drop | ||||
length: 0m. | ||||
3. Sound level: Anechoic chamber conversion value, measured at a point 1 m in front of the unit at a height of *m(1m for 80/105 model,1.2m | ||||
for 120~160 model). During actual operation, these values are normally somewhat higher as a result of ambient conditions. | ||||
4. The above data may be changed without notice for future improvement on quality and performance. |