Operating ambient temperatures
Suggested retail price
Technology
Aluminium heat exchanger with hydrophilic coating
Improved wettability of the heat exchanger aluminum plates which have a special coating with a hydrophilic layer, ensuring rapid removal of condensate from the indoor unit that does not allow to quickly form of mold and bacteria, providing a more efficient operation of the air conditioner.
Wi-Fi Control (Wi-Fi stick)
Mission's Wi-Fi and Smart Kits* are designed for even more comfortable and easy operation (for some series of Wi-Fi stick - option).
Customers can download absolutely free app for your smartphone with the QR-code located in the user's manual.
360°Air Flow Panel
With the 360°air flow panel, the air can be distributed to every corner of the room.
Motor DC inverter indoor unit
The indoor unit is used to rotate the impeller DC - motor. This can significantly reduce noise and power consumption. And also get 12 positions change the speed of the impeller.
Night Mode
Mode is activated with the remote control and provides a comfortable environment for a peaceful and deep sleep during the 7-hour cycle with a temperature change of reference values, as well as setting the minimum noise level and economical energy consumption. After that, the temperature returns to the originally specified value.
Dry Mode
Dry mode automatically selects cooling, based on the difference between fixed and temparaturoy actual room temperature. The temperature is regulated while reducing humidity repeated switching on and off of the cooling and ventilation only. when the dry mode on the remote control shows "Drop"
Multi-Bend Heat Exchanger
Increased heat. This unit uses the heat exchangers with tubes of a special design, the inner surface of which has trapezoidal notches "Innergrove cooper", which provides maximum heat transfer surface area increased. Due to this heat increases by 28%, reduced power consumption, and hence increases the efficiency of the system.
Description
This type of indoor units must be installed, first ensuring the installation of the unit itself, and then, after sewing the ceiling, install a decorative panel with an air filter and shutters that allow the distribution of clean air in a circular direction (additional channels at the corners of the panel, provide a more even airflow ). The deviation of the vertical airflow can be adjusted by setting the blinds in the desired position using the remote control (supplied). All cassette indoor units are equipped with built-in drainage pumps.
Specifications
Indoor model | MCA3I-07HND0 | MCA3I-09HNXD0 | MCA3U-12HRFNX | MCA3U-18HRFNX | MCA3U-24HRFNX | ||
Power supply (Indoor ) | V- Ph-Hz | 220~240-1-50 | 220~240-1-50 | 220~240-1-50 | 220~240-1-50 | 220~240-1-50 | |
Cooling | Capacity | Btu/h | 7000 | 9000 | 12000 | 18000 | 24000 |
Input | W | 40 | 40 | 40 | 102 | 120 | |
Current | A | 0.18 | 0.18 | 0.18 | 0.44 | 0.6 | |
Heating | Capacity | Btu/h | 7500 | 10000 | 14000 | 18500 | 25000 |
Input | W | 40 | 40 | 40 | 102 | 120 | |
current | A | 0.18 | 0.18 | 0.18 | 0.44 | 0.6 | |
Indoor fan motor | Model | ZKFP-46-8-1 | ZKFP-46-8-1 | ZKFP-46-8-1 | ZKFP-46-8-1 | ZKFN-45-8-1 | |
Old Model | WZDK46-38G | WZDK46-38G | WZDK46-38G | WZDK46-38G | --- | ||
Qty | 1 | 1 | 1 | 1 | 1 | ||
Input | W | 45 | 45 | 45 | 45 | 58 | |
Capacitor | uF | - | - | - | / | / | |
Speed(Hi/Mi/Lo) | r/min | 600/520/460 | 600/520/460 | 700/580/500 | 720/625/540 | 608/552/496 | |
Indoor coil | a.Number of rows | 3 | 1 | 1 | 2 | 2 | 2 |
b.Tube pitch(a)x row pitch(b) | mm | 21x13.37 | 21x13.37 | 21x13.37 | 21x13.37 | 21x13.37 | |
c.Fin spacing | mm | 1.3 | 1.3 | 1.3 | 1.3 | 1.3 | |
d.Fin type (code) | Hydrophilic aluminum | Hydrophilic aluminum(Golden) | Hydrophilic aluminum(Golden) | Hydrophilic aluminum(Golden) | Hydrophilic aluminum | ||
e.Tube outside dia.and type | mm | Φ7,Inner groove tube | Φ7,innergroove tube | Φ7,innergroove tube | Φ7,innergroove tube | Φ7,Inner groove tube | |
f.Coil length x height x width | mm | 1380x210x13.37 | 1380x210x13.37 | 1360x210x26.74 | 1360x210x26.74 | 2135x168x26.74 | |
g.Number of circuits | 2 | 2 | 4 | 4 | 4 | ||
Indoor air flow (Hi/Mi/Lo) | m3/h | 580/500/450 | 580/500/450 | 617/504/415 | 680/560/500 | 1247/1118/992 | |
Indoor sound pressure level (Hi) | dB(A) | 37.0/33.0/31.5 | 38/33/29 | 41/37/34 | 44/42/41 | 45/43/40 | |
Indoor sound power level (Hi) | dB(A) | 51 | 53 | 58 | 56 | 59 | |
Indoor unit | Dimension (W x Dx H)(body) | mm | 570x570x260 | 570x570x260 | 570x570x260 | 570x570x260 | 830x830x205 |
Packing (W x Dx H)(body) | mm | 662x662x317 | 662x662x317 | 662x662x317 | 662x662x317 | 950x950x55 | |
Dimension (W x Dx H)(panel) | mm | 647x647x50 | 647x647x50 | 647x647x50 | 647x647x50 | 910x910x250 | |
Packing (W x Dx H)(panel) | mm | 715x715x123 | 715x715x123 | 715x715x123 | 715x715x123 | 1035x1035x90 | |
Net/Gross weight(body) | kg | 14.5/17.3 | 14.5/17.3 | 16.2/21.4 | 16.2/21.4 | 21.6/25.4 | |
Net/Gross weight(panel) | kg | 2.5/4.5 | 2.5/4.5 | 2.5/4.5 | 2.5/4.5 | 6/9 | |
Design pressure | MPa | 4.3/1.7 | 4.3/1.7 | 4.3/1.7 | 4.3/1.7 | 4.2/1.5 | |
Drainage water pipe dia | mm | ODΦ25 | ODΦ25 | ODΦ25 | ODΦ25 | ODΦ25mm | |
Refrigerant piping | Liquid side/ Gas side | mm(inch) | Φ6.35/Φ9.52(1/4"/3/8") | Φ6.35/Φ9.52(1/4"/3/8") | Φ6.35/Φ9.52(1/4"/3/8") | Φ6.35/Φ12.7(1/4"/1/2") | 9.52mm(3/8in)/15.9mm(5/8in) |
Controller | Remote Control | Remote Control | Remote Control | Remote control | Remote control | ||
Room temp | °C | 17~30 | 17~30 | 17~30 | 17~30 | 17~30 | |
Operation temp | Cooling | °C | 17~32 | 17~32 | 17~32 | 17~32 | 17~32 |
Heating | °C | 0~30 | 0~30 | 0~30 | 0~30 | 0~30 |